EUVIMEDEUVIMED entdecken
Crossref

Study on Accuracy of Different Cytoarchitectural Features in the Diagnosis of Papillary Thyroid Carcinoma by Fine Needle Aspiration

Bikash Kumar Singh, Kumar Abi, Jitendra Kumar Sinha

International Journal of Current Pharmaceutical Review and Research · 31.03.2026 · 18 (03)

DOI: 10.25258/ijcpr.18.3.237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 31.03.2026. Verfasst von Bikash Kumar Singh und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In a sufficient sample, the diagnostic accuracy of fine needle aspiration (FNA) for papillary thyroid cancer (PTC) is approximately 90%. Reliance on a single or small number of cytologic features can result in a misdiagnosis if the relative importance of each feature is not understood. Our goal was to ascertain the value of both individual and the best combination of cytologic characteristics for PTC diagnosis.

Methods

The files contained H&E stained FNA smears of fifty cases each of successive histologically confirmed PTC and benign thyroid cases (controls), reported over a three-year period. Blind to the final diagnosis, 31 architectural, cytological, and background characteristics were evaluated and compared between the two groups. Chi-square and odds ratios were used to determine each parameter's statistical significance (p

Zitieren

APA

Singh, B. K., Abi, K., & Sinha, J. K. (2026). Study on Accuracy of Different Cytoarchitectural Features in the Diagnosis of Papillary Thyroid Carcinoma by Fine Needle Aspiration. International Journal of Current Pharmaceutical Review and Research, 18(03). https://doi.org/10.25258/ijcpr.18.3.237

Vancouver

Singh BK, Abi K, Sinha JK. Study on Accuracy of Different Cytoarchitectural Features in the Diagnosis of Papillary Thyroid Carcinoma by Fine Needle Aspiration. International Journal of Current Pharmaceutical Review and Research. 2026;18(03). doi:10.25258/ijcpr.18.3.237

BibTeX
@article{Singh2026,
  author = {Singh, Bikash Kumar and Abi, Kumar and Sinha, Jitendra Kumar},
  title = {Study on Accuracy of Different Cytoarchitectural Features in the Diagnosis of Papillary Thyroid Carcinoma by Fine Needle Aspiration},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {03},
  doi = {10.25258/ijcpr.18.3.237}
}
Kostenlos starten →