EUVIMEDEUVIMED entdecken
Crossref

DIAGNOSTIC ACCURACY OF THE FINE-NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSIS OF SOLID SOLITARY THYROID NODULE

Khalil Ahmed Orakzai, Sadat Ullah Khan, Ihtisham ul Haq, Muhammad Mudassir

Khyber Journal of Medical Sciences · 31.03.2026 · 19 (1)

DOI: 10.70520/kjms.v19i1.764 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Khyber Journal of Medical Sciences, online erschienen am 31.03.2026. Verfasst von Khalil Ahmed Orakzai und 3 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the diagnostic accuracy of fine needle aspiration cytology (FNAC) for solid solitary thyroid nodules, using histopathology as the reference standard. Study Design: Cross-sectional validation study. Place and Duration of Study: Department of ENT, Lady Reading Hospital (MTI), Peshawar, from 01 October 2024 to 31 March 2025. Methodology: Adults (?18 years) with a solitary, predominantly solid thyroid nodule on ultrasonography underwent ultrasound-guided FNAC followed by surgical excision and histopathology. Cytology was reported using the Bethesda System for Reporting Thyroid Cytopathology (TBSRTC). For diagnostic accuracy analysis, Bethesda II was considered benign (test negative) and Bethesda V–VI malignant (test positive); non-diagnostic (Bethesda I) and indeterminate categories (Bethesda III–IV) were excluded from the primary 2×2 analysis. Cytology and histopathology were interpreted independently with blinding to each other’s reports. Sensitivity, specificity, PPV, NPV, and accuracy were calculated with 95% confidence intervals (CI).

Results

A total of 110 patients were included; mean age was 45.81±16.24 years, and 63 (57.3%) were males. Histopathology confirmed 50 (45.5%) malignant and 60 (54.5%) benign nodules. FNAC showed sensitivity 84.00% (95% CI: 71.50–91.67), specificity 88.33% (95% CI: 77.79–94.22), PPV 85.71% (95% CI: 73.29–92.91), NPV 86.89% (95% CI: 76.17–93.23), and accuracy 86.36% (95% CI: 78.69–91.63).

Conclusion

In this single-centre surgical cohort, FNAC demonstrated good diagnostic performance for solid solitary thyroid nodules; however, false-negative and false-positive results occurred, so FNAC should be interpreted alongside clinical and ultrasound risk features, with repeat sampling or alternate techniques when suspicion persists.

Zitieren

APA

Orakzai, K. A., Khan, S. U., Haq, I. U., & Mudassir, M. (2026). DIAGNOSTIC ACCURACY OF THE FINE-NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSIS OF SOLID SOLITARY THYROID NODULE. Khyber Journal of Medical Sciences, 19(1). https://doi.org/10.70520/kjms.v19i1.764

Vancouver

Orakzai KA, Khan SU, Haq IU, Mudassir M. DIAGNOSTIC ACCURACY OF THE FINE-NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSIS OF SOLID SOLITARY THYROID NODULE. Khyber Journal of Medical Sciences. 2026;19(1). doi:10.70520/kjms.v19i1.764

BibTeX
@article{Orakzai2026,
  author = {Orakzai, Khalil Ahmed and Khan, Sadat Ullah and Haq, Ihtisham ul and Mudassir, Muhammad},
  title = {DIAGNOSTIC ACCURACY OF THE FINE-NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSIS OF SOLID SOLITARY THYROID NODULE},
  journal = {Khyber Journal of Medical Sciences},
  year = {2026},
  volume = {19},
  number = {1},
  doi = {10.70520/kjms.v19i1.764}
}
Kostenlos starten →