Dosimetric evaluation of an ipsilateral intensity modulated radiotherapy beam arrangement for parotid malignancies
Radiology and Oncology · 2013
DOI: 10.2478/raon-2013-0010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiology and Oncology, 2013. Verfasst von Eda Yirmibesoglu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Kocaeli University Faculty of Medicine, Kocaeli, Turkey ; Department of Radiation Oncology, University of North Car…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
We conducted a dosimetric comparison of an ipsilateral beam arrangement for intensity modulated radiotherapy (IMRT) with off-axis beams. Patients and methods. Six patients who received post-operative radiotherapy (RT) for parotid malignancies were used in this dosimetric study. Four treatment plans were created for each CT data set (24 plans): 1) ipsilateral 4-field off-axis IMRT (4fld-OA), 2) conventional wedge pair (WP), 3) 7 field co-planar IMRT (7fld), and 4) ipsilateral co-planar 4-field quartet IMRT (4fld-CP). Dose, volume statistics for the planning target volumes (PTVs) and planning risk volumes (PRVs) were compared for the four treatment techniques.
Results
Wedge pair plans inadequately covered the deep aspect of the PTV. The 7-field IMRT plans delivered the largest low dose volumes to normal tissues. Mean dose to the contralateral parotid was highest for 7 field IMRT. Mean dose to the contralateral submandibular gland was highest for 7 field IMRT and WP. 7 field IMRT plans had the highest dose to the oral cavity. The mean doses to the brainstem, spinal cord, ipsilateral temporal lobe, cerrebellum and ipsilateral cochlea were similar among the four techniques.
Conclusions
For postoperative treatment of the parotid bed, 4-field ipsilateral IMRT techniques provided excellent coverage while maximally sparing the contralateral parotid gland and submandibular gland.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Kocaeli University Faculty of Medicine, Kocaeli, Turkey ; Department of Radiation Oncology, University of North Carolina Hospitals, Chapel Hill, NC, USA.
Zitieren
APA
Yirmibesoglu, E., Fried, D. V., Kostich, M., Rosenman, J., Shockley, W., Weissler, M., Zanation, A., & Chera, B. (2013). Dosimetric evaluation of an ipsilateral intensity modulated radiotherapy beam arrangement for parotid malignancies. Radiology and Oncology. https://doi.org/10.2478/raon-2013-0010
Vancouver
Yirmibesoglu E, Fried DV, Kostich M, Rosenman J, Shockley W, Weissler M, et al. Dosimetric evaluation of an ipsilateral intensity modulated radiotherapy beam arrangement for parotid malignancies. Radiology and Oncology. 2013. doi:10.2478/raon-2013-0010
BibTeX
@article{Yirmibesoglu2013,
author = {Yirmibesoglu, Eda and Fried, David V and Kostich, Mark and Rosenman, Julian and Shockley, William and Weissler, Mark and Zanation, Adam and Chera, Bhishamjit},
title = {Dosimetric evaluation of an ipsilateral intensity modulated radiotherapy beam arrangement for parotid malignancies},
journal = {Radiology and Oncology},
year = {2013},
doi = {10.2478/raon-2013-0010}
}
EUVIMED