EUVIMEDEUVIMED entdecken
Crossref

Dosimetric comparison of different intensity-modulated radiotherapy techniques for whole-breast irradiation of right-breast cancer

Y-Q Song, J Hong, J-Y Wang, J Peng, J-H Han, H-L Luo

Cancer/Radiothérapie · 2023-02 · 27 (1) · 11-16

DOI: 10.1016/j.canrad.2022.04.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cancer/Radiothérapie, 2023-02. Verfasst von Y-Q Song und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The Affiliated Huaian No. 1 People's Hospital of Nanjing Medical University, 223300 Huaian Jiangsu, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study compared the dosimetric parameters of field-in-field forward intensity-modulated radiotherapy (FIF-IMRT) and fixed-field inversely optimized intensity-modulated radiotherapy (FFIO-IMRT) for the whole-breast irradiation of patients undergoing right-breast lumpectomy. MATERIAL AND METHODS: A total of 30 patients with pT1-2N0M0 right-breast invasive ductal carcinoma were enrolled in this study. Two different treatment plans, i.e., FIF-IMRT and FFIO-IMRT, were designed for each patient. The dosimetric parameters of the two treatment plans were compared including ipsilateral lung and heart, conformity index (CI), and the homogeneity index (HI) of the planning target volume (PTV). RESULTS: Fixed-field inversely optimized intensity-modulated radiotherapy was found to significantly improve CI (83.302% vs. 60.146%) and HI (11.837% vs. 19.280%), and significantly reduced V25 (18.038% vs. 19.653%) and V30 (15.790% vs. 18.492%) of the ipsilateral lung. It also significantly increased V5 (69.791% vs. 32.615%) of the ipsilateral lung and V5 (61.579% vs. 3.829%), V10 (14.130% vs. 0.381%), V20 (1.843% vs. 0.051%), and Dmean (5.211Gy vs. 1.870Gy) of the heart. CONCLUSION: Regardless of improving the conformity and homogeneity of PTV and reducing the ipsilateral lung irradiation volume at high doses, FFIO-IMRT significantly raised the ipsilateral lung irradiated volume at low doses, as well as the irradiation volume and mean radiation doses to the heart. This limits its use in patients with early-stage right breast cancer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsRadiotherapy, Intensity-ModulatedHumansFemaleRadiotherapy Planning, Computer-AssistedBreastRadiometryRadiotherapy DosageOrgans at Risk

Stichwörter der Autor:innen

Breast cancerBreast lumpectomyCancer du seinDosimetric parametersIMRTParamètres dosimétriquesRadiothérapie du sein entierTumorectomie du seinWhole-breast radiation therapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, The Affiliated Huaian No. 1 People's Hospital of Nanjing Medical University, 223300 Huaian Jiangsu, China.
  • Department of Radiation Oncology, The Affiliated Huaian No. 1 People's Hospital of Nanjing Medical University, 223300 Huaian Jiangsu, China. Electronic address: luohonglei07@outlook.com.

Zitieren

APA

Song, Y. Q., Hong, J., Wang, J. Y., Peng, J., Han, J. H., & Luo, H. L. (2023). Dosimetric comparison of different intensity-modulated radiotherapy techniques for whole-breast irradiation of right-breast cancer. Cancer/Radiothérapie, 27(1), 11-16. https://doi.org/10.1016/j.canrad.2022.04.009

Vancouver

Song YQ, Hong J, Wang JY, Peng J, Han JH, Luo HL. Dosimetric comparison of different intensity-modulated radiotherapy techniques for whole-breast irradiation of right-breast cancer. Cancer/Radiothérapie. 2023;27(1):11-16. doi:10.1016/j.canrad.2022.04.009

BibTeX
@article{Song2023,
  author = {Song, Y-Q and Hong, J and Wang, J-Y and Peng, J and Han, J-H and Luo, H-L},
  title = {Dosimetric comparison of different intensity-modulated radiotherapy techniques for whole-breast irradiation of right-breast cancer},
  journal = {Cancer/Radiothérapie},
  year = {2023},
  volume = {27},
  number = {1},
  pages = {11--16},
  doi = {10.1016/j.canrad.2022.04.009}
}