EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 3.0

Screening method for the determination of selected tetracyclines in water by liquid chromatography with diode array detector

Ewelina Patyra, Ewelina Kowalczyk, Krzysztof Kwiatek

Bulletin of the Veterinary Institute in Pulawy · 01.03.2014 · 58 (1) · 65-70

DOI: 10.2478/bvip-2014-0010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of the Veterinary Institute in Pulawy, online erschienen am 25.03.2014. Verfasst von Ewelina Patyra und 2 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A chromatographic procedure for determination of oxytetracycline (OXT), tetracycline (TC), chlorotetracycline (CTC), and doxycycline (DC) in water samples was developed and was applied for the analysis of water samples collected from poultry and pig farms and environmental water samples. Samples were acidified with trifluoroacetetic acid to pH 3 and further purified by solid phase extraction using Oasis HLB cartridges. The samples were dried up and redissolved in the mixture of oxalic acid and methanol. Separation was performed on reserved phase column (Phenomenex column C18 , 250 mm × 4.6 mm, 5 μm) by multistep gradient elution, and detection was carried out at 360 nm for OTC and TC, 370 nm for CTC, and 350 nm for DC. The tetracyclines were eluted with the mobile phase of 0.05 M oxalic acid (pH 2.5), acetonitrile, and methanol. This method provided average recoveries of 83.53% to 108.59%, with coefficient of variations (CVs) of 2.41% to 8.64% in the range of 10 to 1000 μg/L OTC, TC, CTC, and DC in water. The linearity for the tetracyclines was determined by HPLC-DAD in the range 10 to 1000 μg/L, with the correlation coefficient (R) > 0.99. The LOD and LOQ for the tetracyclines in water samples ranged from 1.51 to 4.00 and 2.51 to 5.93 μg/L, respectively.

Zitieren

APA

Patyra, E., Kowalczyk, E., & Kwiatek, K. (2014). Screening method for the determination of selected tetracyclines in water by liquid chromatography with diode array detector. Bulletin of the Veterinary Institute in Pulawy, 58(1), 65-70. https://doi.org/10.2478/bvip-2014-0010

Vancouver

Patyra E, Kowalczyk E, Kwiatek K. Screening method for the determination of selected tetracyclines in water by liquid chromatography with diode array detector. Bulletin of the Veterinary Institute in Pulawy. 2014;58(1):65-70. doi:10.2478/bvip-2014-0010

BibTeX
@article{Patyra2014,
  author = {Patyra, Ewelina and Kowalczyk, Ewelina and Kwiatek, Krzysztof},
  title = {Screening method for the determination of selected tetracyclines in water by liquid chromatography with diode array detector},
  journal = {Bulletin of the Veterinary Institute in Pulawy},
  year = {2014},
  volume = {58},
  number = {1},
  pages = {65--70},
  doi = {10.2478/bvip-2014-0010}
}
Kostenlos starten →