EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accurate Determination of 24 Water-Soluble Synthetic Colorants in Premade Cocktail Using Ultra-Performance Liquid Chromatography with Diode Array Detection

Kang Ma, Yiwen Zhang, Taipeng Wu

Beverages · 12.06.2025 · 11 (3) · 91

DOI: 10.3390/beverages11030091 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Beverages, online erschienen am 12.06.2025. Verfasst von Kang Ma und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, Project of Research of Reference Materials for the Safety Supervision of Feed and Livestock Product Quality.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A rapid, traceable, and highly sensitive method was developed for the simultaneous separation and quantification of 24 water-soluble synthetic colorants in premade cocktails, utilizing ultra-performance liquid chromatography coupled with diode array detection (UPLC-DAD). The purity of each colorant was individually confirmed through multi-wavelength analysis. Chromatographic conditions, including mobile phase composition and gradient elution, were meticulously optimized, achieving the separation of the 24 colorants on a BEH C18 column using a linear gradient elution within 16 min. The mobile phase consisted of an ammonium acetate solution (100 mmol/L, pH 6.25) and a mixed organic solvent of methanol and acetonitrile (2:8, v/v). The method exhibited excellent linearity across the concentration range of 0.005–10 μg/mL, with limits of detection (LODs) ranging from 0.66 to 27.78 μg/L for all 24 colorants. The method also demonstrated good precision (0.1–4.9%) at various concentration levels and recoveries ranging from 87.8% to 104.5% at spiked concentrations of 0.1, 0.5, and 1.0 μg/mL. A comparison with other published methods for colorant determination in food samples using HPLC-DAD and LC-MS (2014–2024) revealed that the proposed method offers superior performance in terms of the number of analytes detected, lower limits of detection, and reduced analytical time. Finally, the method was successfully applied to the analysis of colorants in premade cocktails from different sources.

Förderung

  • National Key R&D Program of China, Project of Research of Reference Materials for the Safety Supervision of Feed and Livestock Product Quality

Zitieren

APA

Ma, K., Zhang, Y., & Wu, T. (2025). Accurate Determination of 24 Water-Soluble Synthetic Colorants in Premade Cocktail Using Ultra-Performance Liquid Chromatography with Diode Array Detection. Beverages, 11(3), 91. https://doi.org/10.3390/beverages11030091

Vancouver

Ma K, Zhang Y, Wu T. Accurate Determination of 24 Water-Soluble Synthetic Colorants in Premade Cocktail Using Ultra-Performance Liquid Chromatography with Diode Array Detection. Beverages. 2025;11(3):91. doi:10.3390/beverages11030091

BibTeX
@article{Ma2025,
  author = {Ma, Kang and Zhang, Yiwen and Wu, Taipeng},
  title = {Accurate Determination of 24 Water-Soluble Synthetic Colorants in Premade Cocktail Using Ultra-Performance Liquid Chromatography with Diode Array Detection},
  journal = {Beverages},
  year = {2025},
  volume = {11},
  number = {3},
  pages = {91},
  doi = {10.3390/beverages11030091}
}
Kostenlos starten →