EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparative Experimental Evaluation of a Current Transformer and a Hall‑Effect Current Probe Used for Monitoring Active Electrical Power Absorbed by AC Drive Motors

Constantin-Gheorghe Mihai, Cristiana Bişoc Grigoruţă, Mohammed Khdair, Lucian-Claudiu Grigoruţă, Mihăiţă Horodincă

Bulletin of the Polytechnic Institute of Iași. Machine constructions Section · 01.03.2026 · 72 (1) · 53-69

DOI: 10.2478/bipcm-2026-0004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of the Polytechnic Institute of Iași. Machine constructions Section, online erschienen am 27.06.2026. Verfasst von Constantin-Gheorghe Mihai und 4 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a comparative experimental study on the use of a toroidal AC current transformer and a Hall‑effect‑based current probe for measuring the instantaneous AC current absorbed by an electric motor driving a mechanical system (e. g. a car gear box, a lathe gear box). The measured AC current waveforms are then used to determine the active electrical power absorbed by the motor, which directly reflects the mechanical power delivered to the driven system. Experiments confirm a well‑known effect: compared to a Hall‑effect current probe (assumed to operate ideally), the AC current transformers introduce a positive phase shift, causing the measured waveform to lead the real current. Because of this positive phase shift, the measured instantaneous voltage and current exhibit an artificially increased phase difference, which leads to an inaccurate estimation of the active electrical power. A method for compensating this drawback is proposed. In addition, several limitations of current transformers in capturing severe transient regimes are illustrated.

Zitieren

APA

Mihai, C., Grigoruţă, C. B., Khdair, M., Grigoruţă, L., & Horodincă, M. (2026). Comparative Experimental Evaluation of a Current Transformer and a Hall‑Effect Current Probe Used for Monitoring Active Electrical Power Absorbed by AC Drive Motors. Bulletin of the Polytechnic Institute of Iași. Machine constructions Section, 72(1), 53-69. https://doi.org/10.2478/bipcm-2026-0004

Vancouver

Mihai C, Grigoruţă CB, Khdair M, Grigoruţă L, Horodincă M. Comparative Experimental Evaluation of a Current Transformer and a Hall‑Effect Current Probe Used for Monitoring Active Electrical Power Absorbed by AC Drive Motors. Bulletin of the Polytechnic Institute of Iași. Machine constructions Section. 2026;72(1):53-69. doi:10.2478/bipcm-2026-0004

BibTeX
@article{Mihai2026,
  author = {Mihai, Constantin-Gheorghe and Grigoruţă, Cristiana Bişoc and Khdair, Mohammed and Grigoruţă, Lucian-Claudiu and Horodincă, Mihăiţă},
  title = {Comparative Experimental Evaluation of a Current Transformer and a Hall‑Effect Current Probe Used for Monitoring Active Electrical Power Absorbed by AC Drive Motors},
  journal = {Bulletin of the Polytechnic Institute of Iași. Machine constructions Section},
  year = {2026},
  volume = {72},
  number = {1},
  pages = {53--69},
  doi = {10.2478/bipcm-2026-0004}
}
Kostenlos starten →