Simultaneous 3D aortic lumen and vessel wall imaging at 0. 55 T at either systole or diastole
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30611 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Matias Paredes und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Aorta, Magnetic Resonance Angiography. Die Arbeit nennt 36 Literaturangaben. Gefördert von: ANID FONDECYT, BHF programme, King's BHF Centre for Award Excellence.
Abstract (Originalsprache)
Purpose
To evaluate the feasibility of a novel, non‐contrast enhanced, 3D, simultaneous bright‐blood, and black‐blood sequence (iT2prep‐BOOST) for aortic imaging at 0.55 T at either systole or diastole.
Methods
Simultaneous contrast‐free 3D aortic lumen and vessel wall imaging at 0.55 T is achieved using the recently introduced iT2prep‐BOOST framework that interleaves the acquisition of two bright blood images (with inversion recovery T 2 preparation [T2prep‐IR] and no preparation). To enable either systolic or diastolic aortic imaging, three T 2 preparation pulses were investigated—an adiabatic RF pulse and two Malcolm‐Levitt (MLEV) pulses (MLEV4 and MLEV8)—to improve image quality in regions with high flow and susceptibility. The proposed approach was evaluated in phantom, 10 healthy subjects and 3 patients with suspected cardiovascular disease. Bright‐ and black‐blood images resulting from the three different T 2 preparation pulses were compared both qualitatively and quantitatively, using a 4‐point Likert scale for vessel sharpness and presence of blood artifacts. Additionally, the contrast ratio between the lumen and myocardium was computed. Aortic measurements, including the aortic annulus area at systole and diastole, cusp‐commissure measurement at the aortic root level during diastole, and aortic diameter at the ascending aortic level during diastole were also performed.
Results
Excellent or good image quality scores were obtained for both bright‐ and black‐blood images with iT2prep‐BOOST at 0.55 T with all three preparation pulses. The use of MLEV8 T 2 preparation scheme improves systolic image quality, reducing the presence of artifacts with a significant difference ( p < 0.05) at the mid descending aorta level. This scheme also increases the contrast ratio between aortic lumen and myocardium, compared to the previously used adiabatic RF T 2 preparation. The aortic root diameter and area were consistent with values reported in the literature for healthy subjects at 1.5 T.
Conclusion
The feasibility of a novel, non‐contrast‐enhanced, 3D aortic imaging framework for simultaneous bright‐blood and black‐blood imaging was demonstrated at 0.55 T for either systole or diastole, with a scan time of 7 min. Good image quality scores and aortic measurements in agreement with literature values at 1.5 T were achieved with the MLEV8 T 2 preparation. Studies in a larger cohort of healthy subjects and patients with aortopathies are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
- Institute of Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- MR Research Collaborations, Siemens Healthcare, Camberley, UK.
- British Heart Foundation Centre of Research Excellence, King's College London, London, UK.
ORCID-Profile: Matias Paredes, Carlos Castillo-Passi
Förderung
- ANID FONDECYT
- BHF programme
- King's BHF Centre for Award Excellence
- EPSRC Centre for Doctoral Training in Medical Imaging
- IMPACT Basal Center
- Fondequip Mayor
- Wellcome EPSRC Centre for Medical Engineering
- Technical University of Munich - Institute for Advanced Study
Zitieren
APA
Paredes, M., Castillo-Passi, C., Kunze, K. P., Fotaki, A., Littlewood, S., Botnar, R. M., & Prieto, C. (2025). Simultaneous 3D aortic lumen and vessel wall imaging at 0. 55 T at either systole or diastole. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30611
Vancouver
Paredes M, Castillo-Passi C, Kunze KP, Fotaki A, Littlewood S, Botnar RM, et al. Simultaneous 3D aortic lumen and vessel wall imaging at 0. 55 T at either systole or diastole. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30611
BibTeX
@article{Paredes2025,
author = {Paredes, Matias and Castillo-Passi, Carlos and Kunze, Karl P and Fotaki, Anastasia and Littlewood, Simon and Botnar, René M and Prieto, Claudia},
title = {Simultaneous 3D aortic lumen and vessel wall imaging at 0. 55 T at either systole or diastole},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30611}
}
EUVIMED