EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Open-face plane orientation of a BioMedtrix biologic fixation acetabular cup can be accurately determined from a lateral radiograph

Owen T Fink, Peter J Lotsikas iD

American Journal of Veterinary Research · 18.08.2026 · 1-10

DOI: 10.2460/ajvr.26.05.0236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, erschienen am 18.08.2026. Verfasst von Owen T Fink und 1 weiteren Autor:innen. Beteiligte Einrichtung: Skylos Sports Medicine, A BluePearl Hospital, Woodstock, MD. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To develop and validate a method to calculate biologic fixation (BFX) acetabular cup open-face plane orientation based on measurements from a lateral radiograph.

Methods

The formulas describing the open-face plane orientation were derived using geometric arguments and trigonometry. To assess the method, an in vitro plastic model of a pelvis was implanted with a BFX acetabular cup. A lateral radiograph of the implanted model was obtained and used to calculate the cup open-face plane orientation using the derived method. Direct measurement of the open-face plane orientation was performed, and the calculated values were compared to the directly measured values. The procedure was repeated with the cup in a different orientation for each trial.

Results

52 trials were performed. The derived calculation method demonstrated high repeatability and reproducibility, with intra- and interobserver intraclass correlation coefficients > 0.94. The direct measurement method demonstrated high reproducibility, with interobserver intraclass correlation coefficients > 0.98. The mean absolute angular difference between the calculated and directly measured orientation vectors was 2.8 ± 1.3°, with 95% of trials within 4.7°.

Conclusions

The open-face plane orientation determined by the derived method agreed closely with the directly measured orientation. Clinical Relevance Knowledge of the BFX open-face plane orientation can inform decisions regarding cup revision, help identify complications associated with cup malpositioning, and allow the surgeon to improve their cup placement performance.

Schlagwörter

Stichwörter der Autor:innen

ALOBFXorientationtotal hip replacementversion

Autor:innen und Institutionen

  • Skylos Sports Medicine, A BluePearl Hospital, Woodstock, MD.

ORCID-Profile: Peter J Lotsikas

Zitieren

APA

Fink, O. T., & Lotsikas, P. J. (2026). Open-face plane orientation of a BioMedtrix biologic fixation acetabular cup can be accurately determined from a lateral radiograph. American Journal of Veterinary Research, 1-10. https://doi.org/10.2460/ajvr.26.05.0236

Vancouver

Fink OT, Lotsikas PJ. Open-face plane orientation of a BioMedtrix biologic fixation acetabular cup can be accurately determined from a lateral radiograph. American Journal of Veterinary Research. 2026:1-10. doi:10.2460/ajvr.26.05.0236

BibTeX
@article{Fink2026,
  author = {Fink, Owen T and Lotsikas, Peter J},
  title = {Open-face plane orientation of a BioMedtrix biologic fixation acetabular cup can be accurately determined from a lateral radiograph},
  journal = {American Journal of Veterinary Research},
  year = {2026},
  pages = {1--10},
  doi = {10.2460/ajvr.26.05.0236}
}
Kostenlos starten →