Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs
American Journal of Veterinary Research · 2026
DOI: 10.2460/ajvr.26.05.0205 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2026. Verfasst von Regan M Stoneburner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Cornell University Hospital for Animals, Ithaca, NY. Hauptthemen laut MEDLINE: Computer-Aided Design, Tomography, X-Ray Computed, Forelimb, Image Processing, Computer-Assisted. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To compare CT measurements of radial geometry obtained using computer-aided design (CAD) software to those obtained using multiplanar reconstruction (MPR) and to compare their intraobserver reliability. We hypothesized that CAD and MPR measurements would be different and that the CAD method would have higher reliability.
Methods
CT images from normal thoracic limbs of dogs scanned from January 1, 2018, through March 1, 2023, were retrospectively collected and analyzed. The CAD and MPR-based measurements in frontal (proximal/distal), sagittal, and torsional planes were made by 1 observer, in triplicate, and compared. Biases and reliability were calculated.
Results
10 right-sided thoracic limbs were included. Median proximal frontal angulation was 3.6° (IQR, −0.7° to 6.2°; valgus) using CAD and −6.8° (IQR, −8.9° to −5.3°; varus) using MPR. The reliability of CAD measurements of sagittal and distal frontal angulation was excellent, whereas the reliability of MPR measurements was moderate for sagittal angulation and poor for distal frontal angulation. There was no difference in reliability between CAD and MPR for proximal frontal or torsional measurements. Agreement between CAD and MPR was poor in all planes.
Conclusions
Measurements of proximal frontal angulation differed between CAD and MPR groups, most likely due to differences in the anatomic features used. The reliability of CAD measurements was equal to or superior to the reliability of MPR measurements. Clinical Relevance Understanding the relationship between CAD and MPR measurements is important as CAD-derived measurements are likely not equivalent to MPR-derived measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Sciences, Cornell University Hospital for Animals, Ithaca, NY.
- Med Dimensions LLC, Rochester, NY.
- Department of Veterinary Clinical Sciences, Colorado State University, Fort Collins, CO.
- Department of Clinical Sciences, Cummings School of Veterinary Medicine, Tufts University, North Grafton, MA.
- Department of Surgical and Radiological Sciences, Weill School of Veterinary Medicine, University of California-Davis, Davis, CA.
ORCID-Profile: Regan M Stoneburner, Jason A Bleedorn, Denis J Marcellin-Little, Selena Tinga
Zitieren
APA
Stoneburner, R. M., Lassinger, L. B., Hayes, G., Bleedorn, J. A., Karlin, W. M., Marcellin-Little, D. J., & Tinga, S. (2026). Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.26.05.0205
Vancouver
Stoneburner RM, Lassinger LB, Hayes G, Bleedorn JA, Karlin WM, Marcellin-Little DJ, et al. Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs. American Journal of Veterinary Research. 2026. doi:10.2460/ajvr.26.05.0205
BibTeX
@article{Stoneburner2026,
author = {Stoneburner, Regan M and Lassinger, Lucas B and Hayes, Galina and Bleedorn, Jason A and Karlin, William M and Marcellin-Little, Denis J and Tinga, Selena},
title = {Measurements of radial angulation using computer-aided design software provide equal or superior reliability to multiplanar computed tomographic reconstruction in dogs},
journal = {American Journal of Veterinary Research},
year = {2026},
doi = {10.2460/ajvr.26.05.0205}
}
EUVIMED