EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Feline caudal vena cava-to-aorta ratio and left atrial-to-aortic root ratio increase in acute hypervolemia

Adam Whitelock iD, Katherine Nash iD, Keely Sayer, Wendy Goodwin iD

American Journal of Veterinary Research · 2025

DOI: 10.2460/ajvr.25.04.0114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2025. Verfasst von Adam Whitelock und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Vena Cava, Inferior, Cat Diseases, Aorta, Heart Atria. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the caudal vena cava-to-aorta (CVC:Ao) ratio at the hepatorenal location and left atrial-to-aortic root (LA:Ao) ratio as ultrasonographic indicators of acute hypervolemia in cats.

Methods

10 healthy adult cats underwent general anesthesia with sevoflurane and were experimentally administered incremental volumes of lactated Ringer solution to achieve cumulative blood volume increases of 50%, 100%, 150%, and 200%. Point-of-care ultrasound measurements of the CVC:Ao and LA:Ao ratios were obtained at baseline, following each fluid bolus, and 15 minutes after the final infusion. All measurements were performed in triplicate.

Results

Both CVC:Ao and LA:Ao ratios demonstrated increases from baseline at all time points. Following the initial fluid bolus (50% blood volume), the mean CVC:Ao ratio increased by 47% (mean difference, −0.51; 95% CI, −0.74 to 0.28), and the LA:Ao ratio increased by 26% (mean difference, −0.33; 95% CI, −0.58 to 0.07) from baseline. During the redistribution phase (15 minutes following final infusion), the LA:Ao ratio decreased significantly compared to postinfusion values, while the CVC:Ao ratio did not. Intraobserver reliability was good to excellent for the LA:Ao ratio (intraclass correlation coefficient, 0.88; 95% CI, 0.82 to 0.92) and moderate to good for the CVC:Ao ratio (intraclass correlation coefficient, 0.79; 95% CI, 0.70 to 0.86).

Conclusions

The CVC:Ao and LA:Ao ratios increased during acute hypervolemia in cats. The ultrasonographic measurements demonstrated good to excellent intraobserver reliability. The decrease in the LA:Ao ratio during the redistribution phase supports previous findings regarding rapid crystalloid redistribution in cats. Clinical Relevance The CVC:Ao and LA:Ao ratios may serve as useful indicators of volume status in feline patients; however, studies in conscious clinical patients are warranted to further validate these findings in cats.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vena Cava, InferiorCat DiseasesAortaHeart AtriaAnimalsCatsMaleFemaleUltrasonographyBlood Volume

Stichwörter der Autor:innen

acute hypervolemiacatscaudal vena cava-to-aorta ratiofelineleft atrial-to-aortic root ratio

Autor:innen und Institutionen

ORCID-Profile: Adam Whitelock, Katherine Nash, Wendy Goodwin

Zitieren

APA

Whitelock, A., Nash, K., Sayer, K., & Goodwin, W. (2025). Feline caudal vena cava-to-aorta ratio and left atrial-to-aortic root ratio increase in acute hypervolemia. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.25.04.0114

Vancouver

Whitelock A, Nash K, Sayer K, Goodwin W. Feline caudal vena cava-to-aorta ratio and left atrial-to-aortic root ratio increase in acute hypervolemia. American Journal of Veterinary Research. 2025. doi:10.2460/ajvr.25.04.0114

BibTeX
@article{Whitelock2025,
  author = {Whitelock, Adam and Nash, Katherine and Sayer, Keely and Goodwin, Wendy},
  title = {Feline caudal vena cava-to-aorta ratio and left atrial-to-aortic root ratio increase in acute hypervolemia},
  journal = {American Journal of Veterinary Research},
  year = {2025},
  doi = {10.2460/ajvr.25.04.0114}
}
Kostenlos starten →