EUVIMEDEUVIMED entdecken
Crossref

Use of the subcostal view for obtaining aortic spectral Doppler-derived outflow velocities in cats

E Korzybska, F Edgerton, S-A Dickson, D Shaw, Y M Pereira, M I Oliveira, G Culshaw, R Blake

Journal of Veterinary Cardiology · 2025

DOI: 10.1016/j.jvc.2025.08.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Cardiology, 2025. Verfasst von E Korzybska und 7 weiteren Autor:innen. Beteiligte Einrichtung: University of Edinburgh, The Royal (Dick) School of Veterinary Studies, Easter Bush Campus, Midlothian, EH25 9RG, United Kingdom. Electronic address:…. Hauptthemen laut MEDLINE: Echocardiography, Doppler, Aorta, Cat Diseases. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION/OBJECTIVES: In dogs and foals, spectral Doppler-derived aortic outflow velocities (AVs) obtained from the subcostal (SC) view provide higher values than the left parasternal apical five-chamber (LAp) view. In cats, use of the SC view for obtaining AV has not been reported. The aim of the study was to compare AV from SC and LAp views, assess the impact of patient and echocardiographic variables on the difference and confirm the feasibility of obtaining the SC view in cats. The authors hypothesised that the SC view would be well tolerated and provide higher AV. ANIMALS, MATERIALS AND METHODS: This was a prospective, single-centre, observational study in cats referred for echocardiography. Standard echocardiographic studies were performed that included Lap-derived AV and, where feasible, those from the SC view. Patient compliance, ease of attainment and need for sedation were recorded. Aortic velocities obtained from both views were compared. The influences of patient and echocardiographic variables on the differences in AV were determined. RESULTS: Ninety-three cats were enrolled in the study. Eight cats were excluded due to incomplete data. The final analysis included 85 cats. Most cats (81%) tolerated the SC view. Subcostal AVs were greater than LAp velocities by 0.18 m/s (confidence interval ± 1.25 m/s; P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, DopplerAortaCat DiseasesAnimalsCatsFemaleMaleProspective StudiesEchocardiography

Stichwörter der Autor:innen

CardiologyCardiomyopathyEchocardiographyFelineObstruction

Autor:innen und Institutionen

  • University of Edinburgh, The Royal (Dick) School of Veterinary Studies, Easter Bush Campus, Midlothian, EH25 9RG, United Kingdom. Electronic address: e.korzybska@ed.ac.uk.
  • University of Edinburgh, The Royal (Dick) School of Veterinary Studies, Easter Bush Campus, Midlothian, EH25 9RG, United Kingdom.

Zitieren

APA

Korzybska, E., Edgerton, F., Dickson, S. A., Shaw, D., Pereira, Y. M., Oliveira, M. I., Culshaw, G., & Blake, R. (2025). Use of the subcostal view for obtaining aortic spectral Doppler-derived outflow velocities in cats. Journal of Veterinary Cardiology. https://doi.org/10.1016/j.jvc.2025.08.001

Vancouver

Korzybska E, Edgerton F, Dickson SA, Shaw D, Pereira YM, Oliveira MI, et al. Use of the subcostal view for obtaining aortic spectral Doppler-derived outflow velocities in cats. Journal of Veterinary Cardiology. 2025. doi:10.1016/j.jvc.2025.08.001

BibTeX
@article{Korzybska2025,
  author = {Korzybska, E and Edgerton, F and Dickson, S-A and Shaw, D and Pereira, Y M and Oliveira, M I and Culshaw, G and Blake, R},
  title = {Use of the subcostal view for obtaining aortic spectral Doppler-derived outflow velocities in cats},
  journal = {Journal of Veterinary Cardiology},
  year = {2025},
  doi = {10.1016/j.jvc.2025.08.001}
}
Kostenlos starten →