Ultrahigh-molecular-weight polyethylene implant improves biomechanical properties for patellar ligament repair in dogs: an ex vivo randomized study
American Journal of Veterinary Research · 2025
DOI: 10.2460/ajvr.25.03.0087 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2025. Verfasst von Romain Lamère und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinique Vétérinaire Evolia, L'Isle Adam, France. Hauptthemen laut MEDLINE: Patellar Ligament, Polyethylenes, Prostheses and Implants. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To assess the biomechanical properties and failure mode of 3 different repair methods in simulated midsubstance canine patella ligament rupture on cadavers.
Methods
The sample was paired hindlimbs of 9 adult mixed-breed dogs. The study design was an experimental study on cadavers. Patellar ligaments were transected and sutured using a Bunnell and simple interrupted epitendinous pattern. They were then randomly reinforced with 1 of 3 techniques: a circumpatellar suture loop anchored distally to the tibial tuberosity (group 1), the same loop combined with a fascia lata strip (group 2), or a polyethylene synthetic implant sutured over the patella proximally and secured distally with an interference screw (group 3). Yield, peak, and failure load, stiffness, and mode of failure were evaluated.
Results
Six hindlimbs were assigned to each group. Augmentation with the synthetic implant (group 3) showed significantly greater yield, peak, and failure load than group 1. There were no significant differences between group 2 and either group 1 or group 3.
Conclusions
Patellar ligament repair augmented with a synthetic ultrahigh-molecular-weight polyethylene implant offered greater tensile strength than a Bunnell suture with an adjunction of a circumpatellar repair. Clinical Relevance The use of a synthetic ultrahigh-molecular-weight polyethylene implant may offer a viable surgical option for patellar ligament repair. Further studies are warranted to assess the long-term outcome in vivo in patients with injured patellar ligament.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinique Vétérinaire Evolia, L'Isle Adam, France.
- Small Animal Surgery Department, VetAgro Sup, Lyon University, Marcy l'Étoile, France.
- ICE Research Unit, UPSP 2016-A104, VetAgro Sup, Lyon University, Marcy l'Etoile, France.
ORCID-Profile: Romain Lamère
Zitieren
APA
Lamère, R., Guillet, M., Scotti, S., Ragetly, C., & Cachon, T. (2025). Ultrahigh-molecular-weight polyethylene implant improves biomechanical properties for patellar ligament repair in dogs: an ex vivo randomized study. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.25.03.0087
Vancouver
Lamère R, Guillet M, Scotti S, Ragetly C, Cachon T. Ultrahigh-molecular-weight polyethylene implant improves biomechanical properties for patellar ligament repair in dogs: an ex vivo randomized study. American Journal of Veterinary Research. 2025. doi:10.2460/ajvr.25.03.0087
BibTeX
@article{Lamre2025,
author = {Lamère, Romain and Guillet, Maxime and Scotti, Stefano and Ragetly, Chantal and Cachon, Thibaut},
title = {Ultrahigh-molecular-weight polyethylene implant improves biomechanical properties for patellar ligament repair in dogs: an ex vivo randomized study},
journal = {American Journal of Veterinary Research},
year = {2025},
doi = {10.2460/ajvr.25.03.0087}
}
EUVIMED