Time but not storage of equine plasma in silicate-coated tubes affects adrenocorticotropic hormone stability
American Journal of Veterinary Research · 2025
DOI: 10.2460/ajvr.24.11.0362 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2025. Verfasst von Taylah J Johnston und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Veterinary Science, The University of Queensland, Gatton, QLD, Australia. Hauptthemen laut MEDLINE: Adrenocorticotropic Hormone, Horse Diseases, Pituitary Diseases, Blood Specimen Collection. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
Pituitary pars intermedia dysfunction (PPID) is diagnosed by measuring the ACTH concentrations. Due to the reported instability of ACTH, it is recommended to transfer centrifuged plasma into cryovials; however, in practice, cryovials are infrequently used, and serum (red-top) tubes are used instead. This study investigated whether this procedure affects ACTH concentrations and the diagnosis of PPID.
Methods
This was a cohort study. Blood was collected into EDTA tubes from 9 horses with PPID and 7 controls. After centrifugation, plasma was either aliquoted into a cryovial or into a serum tube. Samples were stored at 4 and 20 °C with ACTH concentrations measured using a chemiluminescent assay at 2, 24, and 48 hours after collection. Data were analyzed using a 2-way repeated measures ANOVA with P < .05 considered significant.
Results
There was a significant effect of time on ACTH concentrations in horses with PPID at 4 and 20 °C and in all horses at 20 °C with decreasing ACTH concentrations over time; however, no significant effect of storing plasma in a serum tube was detected. Three horses diagnosed with PPID would have had a different classification if the samples had been kept at 20 °C for 24 or 48 hours.
Conclusions
Time but not storage of plasma in serum tubes decreases the measured ACTH concentration in horses with PPID. Clinical Relevance Transferring plasma into serum tubes does not significantly alter the measured ACTH concentrations; however, time between collection and analysis might lead to erroneous diagnoses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Veterinary Science, The University of Queensland, Gatton, QLD, Australia.
- Boehringer Ingelheim Animal Health USA Inc, Duluth, GA.
- College of Veterinary Medicine, Purdue University, West Lafayette, IN.
ORCID-Profile: François-René Bertin
Zitieren
APA
Johnston, T. J., Stewart, A. J., Dryburgh, E. L., & Bertin, F. R. (2025). Time but not storage of equine plasma in silicate-coated tubes affects adrenocorticotropic hormone stability. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.11.0362
Vancouver
Johnston TJ, Stewart AJ, Dryburgh EL, Bertin FR. Time but not storage of equine plasma in silicate-coated tubes affects adrenocorticotropic hormone stability. American Journal of Veterinary Research. 2025. doi:10.2460/ajvr.24.11.0362
BibTeX
@article{Johnston2025,
author = {Johnston, Taylah J and Stewart, Allison J and Dryburgh, Elizabeth L and Bertin, François-René},
title = {Time but not storage of equine plasma in silicate-coated tubes affects adrenocorticotropic hormone stability},
journal = {American Journal of Veterinary Research},
year = {2025},
doi = {10.2460/ajvr.24.11.0362}
}