EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The ACTH ratio validates the thyrotropin-releasing hormone stimulation test to diagnose pituitary pars intermedia dysfunction but does not enhance performance

Jenni R E Auvinen iD, Emma D Stapley iD, François-René Bertin iD

American Journal of Veterinary Research · 2026

DOI: 10.2460/ajvr.25.10.0359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2026. Verfasst von Jenni R E Auvinen und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Thyrotropin-Releasing Hormone, Horse Diseases, Adrenocorticotropic Hormone, Pituitary Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the diagnostic performance of a post-/pre–thyrotropin-releasing hormone (TRH) plasma ACTH ratio for the diagnosis of pituitary pars intermedia dysfunction (PPID) in horses.

Methods

This was a prospective, case-controlled study conducted monthly from January through December 2018 on 21 horses with PPID and 63 control horses. The ratios were calculated by dividing the plasma ACTH concentration obtained 30 minutes after IV injection of TRH by the pre-TRH plasma ACTH concentration. The effect of PPID and month were assessed using a linear mixed-effect model, and the diagnostic performance of the ratio, including accuracy, sensitivity, and specificity, was assessed via receiver operating characteristic curves. Diagnostic cutoff values were calculated via the Youden index when relevant.

Results

Both PPID status and month had a significant effect on post-/pre-TRH plasma ACTH ratio, with higher ratios in horses with PPID in 7 of 12 months. The diagnostic performance of the post-/pre-TRH plasma ACTH ratio varied by month, with accuracies ranging from fair to good but consistently low positive likelihood ratios.

Conclusions

The post-/pre-TRH ACTH ratio allows evaluation of the pituitary pars intermedia response, validating the use of the TRH stimulation test in the diagnosis of PPID. However, the post-/pre-TRH plasma ACTH ratio does not improve the diagnostic characteristics of a TRH stimulation test. Clinical Relevance The TRH stimulation test is recommended for evaluation of the pars intermedia of the equine pituitary gland in the context of diagnosing PPID, but the use of the post-/pre-TRH plasma ACTH ratio does not provide superior performance over the post-TRH ACTH concentration alone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyrotropin-Releasing HormoneHorse DiseasesAdrenocorticotropic HormonePituitary DiseasesPituitary Gland, IntermediateAnimalsHorsesFemaleMaleProspective StudiesCase-Control StudiesSensitivity and Specificity

Stichwörter der Autor:innen

endocrinologygeriatrichorsehypothalamo-pituitary-adrenal axislaminitis

Substanzen

Thyrotropin-Releasing HormoneAdrenocorticotropic Hormone

Autor:innen und Institutionen

ORCID-Profile: Jenni R E Auvinen, Emma D Stapley, François-René Bertin

Zitieren

APA

Auvinen, J. R. E., Stapley, E. D., & Bertin, F. R. (2026). The ACTH ratio validates the thyrotropin-releasing hormone stimulation test to diagnose pituitary pars intermedia dysfunction but does not enhance performance. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.25.10.0359

Vancouver

Auvinen JRE, Stapley ED, Bertin FR. The ACTH ratio validates the thyrotropin-releasing hormone stimulation test to diagnose pituitary pars intermedia dysfunction but does not enhance performance. American Journal of Veterinary Research. 2026. doi:10.2460/ajvr.25.10.0359

BibTeX
@article{Auvinen2026,
  author = {Auvinen, Jenni R E and Stapley, Emma D and Bertin, François-René},
  title = {The ACTH ratio validates the thyrotropin-releasing hormone stimulation test to diagnose pituitary pars intermedia dysfunction but does not enhance performance},
  journal = {American Journal of Veterinary Research},
  year = {2026},
  doi = {10.2460/ajvr.25.10.0359}
}
Kostenlos starten →