Accuracy of oscillometric blood pressure measurement using a Cardell Touch multiparameter monitor in anesthetized pigs
American Journal of Veterinary Research · 2024
DOI: 10.2460/ajvr.24.05.0145 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2024. Verfasst von Stephanie Zeitouneh und 2 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine, Cornell University, Ithaca, NY. Hauptthemen laut MEDLINE: Blood Pressure Determination, Oscillometry. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVE To assess the accuracy of an oscillometric monitor in anesthetized pigs and its ability to track changes in mean arterial pressure (MAP) and to detect arterial hypotension and hypertension in reference to direct measurements. METHODS Mean arterial pressure was measured simultaneously from a catheter in a femoral artery and with an oscillometric cuff placed over the metatarsus in 9 anesthetized pigs (∼6 months old, 35 to 55 kg). Pigs were subjected to maneuvers to alter MAP. Paired values for invasive and noninvasive MAP (iMAP and NiMAP) were recorded every 2 minutes. Bland-Altman plots with bias, limits of agreement, and percentage error were constructed using each pair and the average of 5 consecutive values. Concordance was calculated using changes in MAP at 20-minute intervals. Receiver operating characteristics (ROC) curves were constructed to test NiMAP for detection of hypotension (< 70 mm Hg) and hypertension (≥ 120 mm Hg). RESULTS Bias of NiMAP was −8.59 mm Hg for consecutive pairs and −8.85 mm Hg for averaged pairs, relative to iMAP. Limits of agreement and percentage error were reduced for averages (19%) over individual pairs (26%). Concordance was 82%. The area under the ROC curve for detecting hypotension with NiMAP was 0.936, with a best cutoff value of 63 mm Hg NiMAP. The area under the ROC curve for hypertension was 0.940, with a best cutoff value of 101 mm Hg NiMAP. CONCLUSIONS Averaging several consecutive values improves the accuracy of NiMAP measurements. CLINICAL RELEVANCE This device correctly tracked changes in MAP approximately 80% of the time and appears reliable for diagnosing arterial hypotension.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Veterinary Medicine, Cornell University, Ithaca, NY.
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY.
ORCID-Profile: Manuel Martin-Flores
Zitieren
APA
Zeitouneh, S., Araos, J., & Martin-Flores, M. (2024). Accuracy of oscillometric blood pressure measurement using a Cardell Touch multiparameter monitor in anesthetized pigs. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.05.0145
Vancouver
Zeitouneh S, Araos J, Martin-Flores M. Accuracy of oscillometric blood pressure measurement using a Cardell Touch multiparameter monitor in anesthetized pigs. American Journal of Veterinary Research. 2024. doi:10.2460/ajvr.24.05.0145
BibTeX
@article{Zeitouneh2024,
author = {Zeitouneh, Stephanie and Araos, Joaquin and Martin-Flores, Manuel},
title = {Accuracy of oscillometric blood pressure measurement using a Cardell Touch multiparameter monitor in anesthetized pigs},
journal = {American Journal of Veterinary Research},
year = {2024},
doi = {10.2460/ajvr.24.05.0145}
}
EUVIMED