Validation of the RBP‐9000c Oscillometric Blood Pressure Monitor in the General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard
The Journal of Clinical Hypertension · 2025
DOI: 10.1111/jch.70194 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift The Journal of Clinical Hypertension, 2025. Verfasst von Shijie Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: AnZhen Hospital of the Capital University of Medical Sciences, Beijing, China. Hauptthemen laut MEDLINE: Oscillometry, Blood Pressure Determination, Blood Pressure Monitors, Hypertension. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The aim of this study was to evaluate the accuracy of the single upper‐arm cuff oscillometric blood pressure (BP) monitor RBP‐9000 c developed for office and home blood pressure measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060–2:2018). Subjects were recruited to fulfill the age, gender, BP, and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in the general population using the same‐arm sequential BP measurement method. The test device incorporates a single built‐in cuff suitable for 17–42 cm arm circumference. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.4 ± 6.7/3.3 ± 6.3 mmHg (systolic/ diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.28/5.32 mmHg (systolic/diastolic). The RBP‐9000c oscillometric device for office and home BP measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060–2:2018) in the general population and can be recommended for clinical and self‐use at home. Trial Registration : ChiCTR2300075747
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- AnZhen Hospital of the Capital University of Medical Sciences, Beijing, China.
- Department of Cardiology, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Zitieren
APA
Yang, S., Zhou, Z., Miao, H., & Zhang, Y. (2025). Validation of the RBP‐9000c Oscillometric Blood Pressure Monitor in the General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard. The Journal of Clinical Hypertension. https://doi.org/10.1111/jch.70194
Vancouver
Yang S, Zhou Z, Miao H, Zhang Y. Validation of the RBP‐9000c Oscillometric Blood Pressure Monitor in the General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard. The Journal of Clinical Hypertension. 2025. doi:10.1111/jch.70194
BibTeX
@article{Yang2025,
author = {Yang, Shijie and Zhou, Zhanyang and Miao, Huanhuan and Zhang, Yuqing},
title = {Validation of the RBP‐9000c Oscillometric Blood Pressure Monitor in the General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard},
journal = {The Journal of Clinical Hypertension},
year = {2025},
doi = {10.1111/jch.70194}
}
EUVIMED