A new bipolar precordial electrocardiographic lead configuration for specific evaluation of atrial depolarization in healthy dogs
American Journal of Veterinary Research · 01.01.2024 · 85 (1)
DOI: 10.2460/ajvr.23.07.0151 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, erschienen am 01.01.2024. Verfasst von Kentaro Kurogochi und 2 weiteren Autor:innen. Beteiligte Einrichtung: JASMINE Veterinary Cardiovascular Medical Center, Tsuzuki, Yokohama, Kanagawa, Japan. Hauptthemen laut MEDLINE: Electrocardiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVE The Lewis lead is an EGC configuration used to detect atrial activity and its relationship with ventricular activity. However, no equivalent configuration has been proposed in veterinary medicine. Therefore, this study explored new bipolar lead configurations to evaluate atrial depolarization and investigated their characteristics by comparing them with conventional leads. The authors hypothesized that a lead with a high absolute value of the P wave (|P|) and a high ratio of the P wave to the QRS complex (|P|/|QRS|) might be an appropriate configuration. ANIMALS 6 laboratory Beagles were used. PROCEDURES Electrocardiograms were recorded using bipolar limb leads (I, II, III, aVL, aVF, and aVR) and unipolar precordial leads (C 2 , C 3 , C 4 , C 5 , C 6 , M 1 , M 2 , M 5 , M 6 , 1st-R, CV 6 LL, and V 10 ) in the standing position. The new bipolar leads were attached in the following configuration: the negative electrode was attached to M 6 , and the positive electrode was sequentially applied to M 1 and M 2 . The leads were named M 6 M 1 and M 6 M 2 . RESULTS The waveforms obtained using the new bipolar leads M 6 M 1 and M 6 M 2 showed significantly higher |P|/|QRS| and |P| values than those obtained using conventional limb leads and precordial leads. CLINICAL RELEVANCE The new leads achieved a specific enhancement of atrial activity conducted at a reduced ventricular amplitude and increased atrial amplitude, similar to the Lewis lead in human medicine. These findings suggest that M 6 M 1 and M 6 M 2 could be supplemental lead configurations to identify P waves without amplifying the QRS waves compared to conventional methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- JASMINE Veterinary Cardiovascular Medical Center, Tsuzuki, Yokohama, Kanagawa, Japan.
- Laboratory of Physiology II, Department of Veterinary Medicine, School of Veterinary Medicine, Azabu University, Chuo-ku, Sagamihara, Kanagawa, Japan.
Zitieren
APA
Kurogochi, K., Orito, K., & Uechi, M. (2024). A new bipolar precordial electrocardiographic lead configuration for specific evaluation of atrial depolarization in healthy dogs. American Journal of Veterinary Research, 85(1). https://doi.org/10.2460/ajvr.23.07.0151
Vancouver
Kurogochi K, Orito K, Uechi M. A new bipolar precordial electrocardiographic lead configuration for specific evaluation of atrial depolarization in healthy dogs. American Journal of Veterinary Research. 2024;85(1). doi:10.2460/ajvr.23.07.0151
BibTeX
@article{Kurogochi2024,
author = {Kurogochi, Kentaro and Orito, Kensuke and Uechi, Masami},
title = {A new bipolar precordial electrocardiographic lead configuration for specific evaluation of atrial depolarization in healthy dogs},
journal = {American Journal of Veterinary Research},
year = {2024},
volume = {85},
number = {1},
doi = {10.2460/ajvr.23.07.0151}
}
EUVIMED