Multipolar Electrograms
JACC: Clinical Electrophysiology · 2024
DOI: 10.1016/j.jacep.2024.04.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2024. Verfasst von Elad Anter und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Electrophysiology Institute, Division of Cardiovascular Medicine, Shamir Medical Center, Be'er Yaakov, Faculty of Medicine, Tel Aviv Universi…. Hauptthemen laut MEDLINE: Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Biosense Webster Inc.
Abstract (Originalsprache)
BACKGROUND: Accurate measurements of intracardiac electrograms (EGMs) remain a clinical challenge because of the suboptimal attenuation of far-field potentials. Multielectrode mapping catheters provide an opportunity to construct multipolar instead of bipolar EGMs for rejecting common far-field potentials recorded from a multivectorial space. OBJECTIVES: The purpose of this study was to develop a multipolar EGM and compare its characteristics to those of bipolar EGMs METHODS: Using a 36-electrode array catheter (Optrell-36, Biosense Webster), a far-field component was mathematically constructed from clusters of electrodes surrounding each inspected electrode. This component was subtracted from the unipolar waveform to produce a local unipolar, referred to as a "multipolar EGM." The performance of multipolar EGMs was evaluated in 7 swine with healed anteroseptal infarction. RESULTS: Multipolar EGMs proved superior in attenuating far-field potentials in infarct border zones, increasing the near-field to far-field ratio from 0.92 ± 0.2 to 2.25 ± 0.3 (P < 0.001). Removal of far-field components reduced the voltage amplitude (P < 0.001) and enlarged the infarct surface area (P = 0.02), aligning more closely with histological findings. Of 379 EGMs with ≥20 ms activation time difference between bipolar and multipolar EGMs, 95.3% (361 of 379) were accurately annotated using multipolar EGMs, while annotation based on bipolar EGM was predominantly made on far-field components. CONCLUSIONS: Multielectrode array catheters provide a unique platform for constructing multipolar EGMs. This new EGM may be beneficial for "purifying" local potentials within a complex electrical field, resulting in more accurate voltage and activation maps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Electrophysiology Institute, Division of Cardiovascular Medicine, Shamir Medical Center, Be'er Yaakov, Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; Faculty of Medicine, Tel Aviv University, Tel Av…
- Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
- Biosense Webster, Department of Research and Development, Yokneam, Israel.
- Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
Förderung
- Biosense Webster Inc
Zitieren
APA
Anter, E., Brem, O., Greenbaum, L., Bubar, Z. P., Younis, A., Yavin, H., Yarnitsky, J., & Barkagan, M. (2024). Multipolar Electrograms. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2024.04.009
Vancouver
Anter E, Brem O, Greenbaum L, Bubar ZP, Younis A, Yavin H, et al. Multipolar Electrograms. JACC: Clinical Electrophysiology. 2024. doi:10.1016/j.jacep.2024.04.009
BibTeX
@article{Anter2024,
author = {Anter, Elad and Brem, Ofir and Greenbaum, Lior and Bubar, Zachary P and Younis, Arwa and Yavin, Hagai and Yarnitsky, Jonathan and Barkagan, Michael},
title = {Multipolar Electrograms},
journal = {JACC: Clinical Electrophysiology},
year = {2024},
doi = {10.1016/j.jacep.2024.04.009}
}
EUVIMED