The use of Near Infrared Spectroscopy in measuring haemodynamic response of the primary visual cortex to a visual bullseye stimulus with various spatial and temporal frequencies

Perkins, Luke

PEARL (University of Plymouth) · 08.08.2024 · 4 (2) · 131-154

DOI: 10.24382/zx3z-jb28 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PEARL (University of Plymouth), erschienen am 08.08.2024. Verfasst von Perkins und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The effects of spatial and temporal frequencies of a visual, sinusoidal bullseye stimulus on haemodynamic responses in V1 were investigated using Near-Infrared Spectroscopy. Eight psychology undergraduates viewed a reversing bullseye pattern with differing spatial and temporal frequencies and haemodynamic responses in V1 were measured. It was found that optimum responses were recorded when the spatial frequency was 4.00 c/deg and when temporal frequency was 7.55 Hz; however no significant differences between frequencies were found. The mixed findings provided some support for past findings, implying that cells are finely tuned to detect certain stimulus properties, and demonstrated NIRS as a valid measuring tool in vision research. Future research needs to be conducted in order to improve the quality of the data.

Schlagwörter

near-infrared spectroscopyprimary visual cortexhemodynamic responsespatial frequencytemporal frequencysinusoidal gratingsvisual cortex

Zitieren

APA

Perkins, & Luke (2024). The use of Near Infrared Spectroscopy in measuring haemodynamic response of the primary visual cortex to a visual bullseye stimulus with various spatial and temporal frequencies. PEARL (University of Plymouth), 4(2), 131-154. https://doi.org/10.24382/zx3z-jb28

Vancouver

Perkins, Luke. The use of Near Infrared Spectroscopy in measuring haemodynamic response of the primary visual cortex to a visual bullseye stimulus with various spatial and temporal frequencies. PEARL (University of Plymouth). 2024;4(2):131-154. doi:10.24382/zx3z-jb28

BibTeX
@article{Perkins2024,
  author = {Perkins and Luke},
  title = {The use of Near Infrared Spectroscopy in measuring haemodynamic response of the primary visual cortex to a visual bullseye stimulus with various spatial and temporal frequencies},
  journal = {PEARL (University of Plymouth)},
  year = {2024},
  volume = {4},
  number = {2},
  pages = {131--154},
  doi = {10.24382/zx3z-jb28}
}
Kostenlos starten →