Wearable functional near‐infrared spectroscopy for measuring dissociable activation dynamics of prefrontal cortex subregions during working memory
Human Brain Mapping · 2024-02 · 45 (2)
DOI: 10.1002/hbm.26619 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, online erschienen am 09.02.2024. Verfasst von Jung Han Shin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Program of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea. Hauptthemen laut MEDLINE: Memory, Short-Term, Wearable Electronic Devices. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 89 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
The prefrontal cortex (PFC) has been extensively studied in relation to various cognitive abilities, including executive function, attention, and memory. Nevertheless, there is a gap in our scientific knowledge regarding the functionally dissociable neural dynamics across the PFC during a cognitive task and their individual differences in performance. Here, we explored this possibility using a delayed match‐to‐sample (DMTS) working memory (WM) task using NIRSIT, a high‐density, wireless, wearable functional near‐infrared spectroscopy (fNIRS) system. First, upon presentation of the sample stimulus, we observed an immediate signal increase in the ventral (orbitofrontal) region of the anterior PFC, followed by activity in the dorsolateral PFC. After the DMTS test stimulus appeared, the orbitofrontal cortex activated once again, while the rest of the PFC showed overall disengagement. Individuals with higher accuracy showed earlier and sustained activation of the PFC across the trial. Furthermore, higher network efficiency and functional connectivity in the PFC were correlated with individual WM performance. Our study sheds new light on the dynamics of PFC subregional activity during a cognitive task and its potential applicability in explaining individual differences in experimental, educational, or clinical populations. Practitioner Points Wearable functional near‐infrared spectroscopy (fNIRS) captured dissociable temporal dynamics across prefrontal subregions during a delayed match‐to‐sample task. Anterior regions of the orbitofrontal cortex (OFC) activated first during the delay period, followed by the dorsolateral prefrontal cortex (PFC). PFC disengaged overall after the delay, but the OFC reactivated to the test stimulus. Earlier and sustained activation of PFC was associated with better accuracy. Functional connectivity and network efficiency also varied with task performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Program of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
- Department of Brain and Cognitive Sciences, Seoul National University, Seoul, South Korea.
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea.
ORCID-Profile: Jung Han Shin
Förderung
- National Research Foundation of Korea
Zitieren
APA
Shin, J. H., Kang, M. J., & Lee, S. A. (2024). Wearable functional near‐infrared spectroscopy for measuring dissociable activation dynamics of prefrontal cortex subregions during working memory. Human Brain Mapping, 45(2). https://doi.org/10.1002/hbm.26619
Vancouver
Shin JH, Kang MJ, Lee SA. Wearable functional near‐infrared spectroscopy for measuring dissociable activation dynamics of prefrontal cortex subregions during working memory. Human Brain Mapping. 2024;45(2). doi:10.1002/hbm.26619
BibTeX
@article{Shin2024,
author = {Shin, Jung Han and Kang, Min Jun and Lee, Sang Ah},
title = {Wearable functional near‐infrared spectroscopy for measuring dissociable activation dynamics of prefrontal cortex subregions during working memory},
journal = {Human Brain Mapping},
year = {2024},
volume = {45},
number = {2},
doi = {10.1002/hbm.26619}
}
EUVIMED