EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Mass attenuation coefficients of several water equivalent phantom materials by using Compton scattering technique in comparison to the theoretical XCOM values

Mohd Fahmi Mohd Yusof 1, Puteri Nor Khatijah Abd Hamid 2, Abd Aziz Tajuddin 2, Rokiah Hashim 3, Norriza Mohd Isa 4

Imaging and Radiation Research · 2018

DOI: 10.24294/irr.v0i0.593 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging and Radiation Research, 2018. Verfasst von Mohd Fahmi Mohd Yusof 1 und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The mass attenuation coefficients of several water equivalent phantom materials and fabricated Rhizophora spp. particleboards were measured using Compton scattering technique of Ludlum configuration. The scattered gamma energies were calculated at 30, 45, 60 and 75°. The measured mass attenuation coefficients of the samples were compared to their theoretical values using XCOM calculation soft ware and the XCOM values of water as standard phantom material for high energy photons. The results showed that the measured mass attenuation coefficients of solid water and fabricated Rhizophora spp. particleboards were in good agreement to their respective theoretical values with p-value of 0.2411 and 0.934. A comparison to the XCOM value of water also showed that all experimented values of the water equivalent phantoms were in good agreement to water with p-values between 0.055 and 1. The results had indicated the suitability of the Ludlum configuration to be used for the measurement of mass attenuation coefficients using Compton scattering technique.

Zitieren

APA

1, M. F. M. Y., 2, P. N. K. A. H., 2, A. A. T., 3, R. H., & 4, N. M. I. (2018). Mass attenuation coefficients of several water equivalent phantom materials by using Compton scattering technique in comparison to the theoretical XCOM values. Imaging and Radiation Research. https://doi.org/10.24294/irr.v0i0.593

Vancouver

1 MFMY, 2 PNKAH, 2 AAT, 3 RH, 4 NMI. Mass attenuation coefficients of several water equivalent phantom materials by using Compton scattering technique in comparison to the theoretical XCOM values. Imaging and Radiation Research. 2018. doi:10.24294/irr.v0i0.593

BibTeX
@article{2018,
  author = {1, Mohd Fahmi Mohd Yusof and 2, Puteri Nor Khatijah Abd Hamid and 2, Abd Aziz Tajuddin and 3, Rokiah Hashim and 4, Norriza Mohd Isa},
  title = {Mass attenuation coefficients of several water equivalent phantom materials by using Compton scattering technique in comparison to the theoretical XCOM values},
  journal = {Imaging and Radiation Research},
  year = {2018},
  doi = {10.24294/irr.v0i0.593}
}