Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY · 27.07.2026 · 32 (3) · 292-296
DOI: 10.24293/ijcpml.v32i3.2589 ↗Kurz gefasst
Fachartikel in der Zeitschrift INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY, online erschienen am 27.07.2026. Verfasst von Ratna Agustina und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Urinary tract infections (UTIs) are among the most common infectious diseases globally, accounting for approximately 15% of all hospitalizations. Urine culture is considered the gold standard for diagnosing UTIs. However, this method requires specialized equipment and is time-consuming. In recent years, urine analysis by flow cytometry has begun to be used to detect bacteriuria quickly, accurately, and cost-effectively. The Sysmex UF-5000 uses flow cytometry to differentiate Gram-positive and Gram-negative bacteria, providing “BACT” flagging information. This analytical observational study with a cross-sectional design was conducted at the Integrated Laboratory of Ngoerah Hospital, Denpasar, from April to June 2023. Consecutive urine culture samples with sufficient volume (≥3 mL) were collected for urinalysis. The concordance between the Sysmex UF-5000 flagging and urine culture results was analyzed using Cohen's Kappa test. A total of 50 samples were analyzed. This study demonstrated agreement between the Sysmex UF-5000 flagging results and urine culture findings in differentiating Gram-positive and Gram-negative bacteria, with a Cohen's Kappa coefficient of 0.81. The Sysmex UF-5000 flagging shows excellent agreement or substantial concordance with urine culture results in differentiating Gram-positive and Gram-negative bacteria.
Zitieren
APA
Agustina, R., Lestari, A. A. W., Wande, I. N., Herawati, S., & Mahartini, N. N. (2026). Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY, 32(3), 292-296. https://doi.org/10.24293/ijcpml.v32i3.2589
Vancouver
Agustina R, Lestari AAW, Wande IN, Herawati S, Mahartini NN. Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY. 2026;32(3):292-296. doi:10.24293/ijcpml.v32i3.2589
BibTeX
@article{Agustina2026,
author = {Agustina, Ratna and Lestari, Anak Agung Wiradewi and Wande, I Nyoman and Herawati, Sianny and Mahartini, Ni Nyoman},
title = {Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria},
journal = {INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY},
year = {2026},
volume = {32},
number = {3},
pages = {292--296},
doi = {10.24293/ijcpml.v32i3.2589}
}
EUVIMED