EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria

Ratna Agustina, Anak Agung Wiradewi Lestari, I Nyoman Wande, Sianny Herawati, Ni Nyoman Mahartini

INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY · 27.07.2026 · 32 (3) · 292-296

DOI: 10.24293/ijcpml.v32i3.2589 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY, online erschienen am 27.07.2026. Verfasst von Ratna Agustina und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Urinary tract infections (UTIs) are among the most common infectious diseases globally, accounting for approximately 15% of all hospitalizations. Urine culture is considered the gold standard for diagnosing UTIs. However, this method requires specialized equipment and is time-consuming. In recent years, urine analysis by flow cytometry has begun to be used to detect bacteriuria quickly, accurately, and cost-effectively. The Sysmex UF-5000 uses flow cytometry to differentiate Gram-positive and Gram-negative bacteria, providing “BACT” flagging information. This analytical observational study with a cross-sectional design was conducted at the Integrated Laboratory of Ngoerah Hospital, Denpasar, from April to June 2023. Consecutive urine culture samples with sufficient volume (≥3 mL) were collected for urinalysis. The concordance between the Sysmex UF-5000 flagging and urine culture results was analyzed using Cohen's Kappa test. A total of 50 samples were analyzed. This study demonstrated agreement between the Sysmex UF-5000 flagging results and urine culture findings in differentiating Gram-positive and Gram-negative bacteria, with a Cohen's Kappa coefficient of 0.81. The Sysmex UF-5000 flagging shows excellent agreement or substantial concordance with urine culture results in differentiating Gram-positive and Gram-negative bacteria.

Zitieren

APA

Agustina, R., Lestari, A. A. W., Wande, I. N., Herawati, S., & Mahartini, N. N. (2026). Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY, 32(3), 292-296. https://doi.org/10.24293/ijcpml.v32i3.2589

Vancouver

Agustina R, Lestari AAW, Wande IN, Herawati S, Mahartini NN. Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY. 2026;32(3):292-296. doi:10.24293/ijcpml.v32i3.2589

BibTeX
@article{Agustina2026,
  author = {Agustina, Ratna and Lestari, Anak Agung Wiradewi and Wande, I Nyoman and Herawati, Sianny and Mahartini, Ni Nyoman},
  title = {Concordance Between Sysmex UF-5000 Bacterial Flagging and Urine Culture Results for Differentiating Gram-Positive and Gram-Negative Bacteria},
  journal = {INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY},
  year = {2026},
  volume = {32},
  number = {3},
  pages = {292--296},
  doi = {10.24293/ijcpml.v32i3.2589}
}
Kostenlos starten →