Impact of Cut-out-rescan and Data Exchange by Over-scanning Techniques on Marginal Fit of CAD/CAM Lithium Disilicate Crowns
Operative Dentistry · 2024
DOI: 10.2341/24-024-l ↗Kurz gefasst
Fachartikel in der Zeitschrift Operative Dentistry, 2024. Verfasst von L Passos und 2 weiteren Autor:innen. Beteiligte Einrichtung: *Leandro Passos, DDS, MS, PhD, graduate teaching assistant, Operative Dentistry & Biomaterials, Division of Comprehensive Oral Health, Adams School o…. Hauptthemen laut MEDLINE: Crowns, Dental Porcelain, Computer-Aided Design, Dental Marginal Adaptation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben.
Abstract (Originalsprache)
Objective
Evaluate the impact of adjustment procedures — cut-out-rescan (COR) and data exchange by over-scanning (DEOS) techniques — through CAD/CAM software on the marginal fit outcome of ceramic crowns. Methods and Materials: Twenty-eight de-identified teeth were adapted in a mandibular typodont set. Tooth #19 was prepared for a lithium disilicate crown and seven groups, G0 to G6 (n=10), were created based on the rescanned areas (mesial and/or buccal) on the typodont using an intraoral scanner through COR or DEOS techniques. A digital workflow was used to design and mill 70 crowns according to the groups. Each crown was temporarily cemented on tooth #19 and scanned with micro-computed tomography to measure the marginal fit. The data were analyzed statistically by the Kruskal-Wallis test followed by the Mann-Whitney test to compare the groups pairwise as a post-hoc (α=0.05).
Results
Statistically significant differences were found for vertical misfit (μm) between the groups for Marginal Gap Buccal (MGB) and Marginal Gap Mesial (MGM) ( p =0.003 and p =0.029, respectively). No significant difference was found for Finish Line Buccal (FLB) and Finish Line Mesial (FLM) ( p =0.062 and p =0.092, respectively). G3 (COR buccal and mesial) had the highest MGB (57.75 μm), statistically different from all other groups. G4 (DEOS buccal) (41.60 μm) was different from G6 (DEOS buccal and mesial) (44.21 μm) ( p =0.023). For MGM, G0 (control) (53.96 μm) was different from G5 (DEOS mesial) (45.76 μm) and G6 (DEOS buccal and mesial) (48.56 vm) ( p =0.013 and p=0.041, respectively) and G2 (COR mesial) (58.43 μm) was different from G5 (DEOS mesial) (45.76 μm) ( p =0.016).
Conclusions
Despite a statistically significant difference in certain groups for both techniques, COR and DEOS techniques are viable options for image editing during acquisition. Lithium disilicate crowns can be produced with satisfactory marginal gap values utilizing a chairside CAD/CAM system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- *Leandro Passos, DDS, MS, PhD, graduate teaching assistant, Operative Dentistry & Biomaterials, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina, Chapel Hill, NC, USA.
- Marta Musskopf, DDS, MS, PhD, clinical associate professor, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina, Chapel Hill, NC, USA.
- Adalberto Bastos Vasconcellos, DDS, MS, PhD, professor and graduate program director, Operative Dentistry & Biomaterials, Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina, C…
Zitieren
APA
Passos, L., Musskopf, M., & Vasconcellos, A. B. (2024). Impact of Cut-out-rescan and Data Exchange by Over-scanning Techniques on Marginal Fit of CAD/CAM Lithium Disilicate Crowns. Operative Dentistry. https://doi.org/10.2341/24-024-l
Vancouver
Passos L, Musskopf M, Vasconcellos AB. Impact of Cut-out-rescan and Data Exchange by Over-scanning Techniques on Marginal Fit of CAD/CAM Lithium Disilicate Crowns. Operative Dentistry. 2024. doi:10.2341/24-024-l
BibTeX
@article{Passos2024,
author = {Passos, L and Musskopf, M and Vasconcellos, A B},
title = {Impact of Cut-out-rescan and Data Exchange by Over-scanning Techniques on Marginal Fit of CAD/CAM Lithium Disilicate Crowns},
journal = {Operative Dentistry},
year = {2024},
doi = {10.2341/24-024-l}
}
EUVIMED