An In Vitro Study of Retention and Marginal Adaptation of Endocrowns With Different Intracoronal Depths
Operative Dentistry · 2024
DOI: 10.2341/23-063-l ↗Kurz gefasst
Fachartikel in der Zeitschrift Operative Dentistry, 2024. Verfasst von E C Tiew und 4 weiteren Autor:innen. Beteiligte Einrichtung: Eng Cheong Tiew, BDS, MFDS, National University of Malaysia: Universiti Kebangsaan, Malaysia. Hauptthemen laut MEDLINE: Dental Marginal Adaptation, Crowns, Computer-Aided Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
Background
Marginal adaptation and retention of endocrowns are crucial for the success and survival of endocrowns. This study aimed to investigate the effect of different materials and intracoronal depth on the retention and marginal adaptation of CAD/CAM fabricated all-ceramic endocrowns.
Methods
Thirty-six mandibular premolar teeth with an average surface area of 64.49 mm 2 were prepared to receive CAM/CAM fabricated endocrowns. Samples were divided randomly and equally into groups of lithium disilicate with 2 mm intracoronal depth (LD2), lithium disilicate with 4 mm intracoronal depth (LD4), polymer infiltrated ceramic network with 2 mm intracoronal depth (PICN2) and polymer infiltrated ceramic network with 4 mm intracoronal depth (PICN4). All endocrowns were cemented using ParaCore resin cement with 14N pressure and cured for 20 seconds. Fifty measurements of absolute marginal discrepancy (AMD) were done using a stereomicroscope after cementation. After 24 hours, all samples were subjected to thermocycling before the retention test. This involved using a universal testing machine with a crosshead speed of 0.5 mm/min and applying a load of 500N. The maximum force to detach the crown was recorded in newtons and the mode of failure was identified.
Results
Two-way ANOVA revealed that the AMD for PICN was statistically significantly better than lithium disilicate ( p =0.01). No statistically significant difference was detected in the AMD between the two intracoronal depths ( p =0.72). PICN and endocrowns with 4 mm intracoronal depth had statistically significant better retention ( p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Eng Cheong Tiew, BDS, MFDS, National University of Malaysia: Universiti Kebangsaan, Malaysia.
- Nik Madihah Nik Azis, BDS, DClinDent, National University of Malaysia: Universiti Kebangsaan, Malaysia.
- Lay Ann Teh, MFD RCS, DClinDent, M Endo RCS, National University of Malaysia: Universiti Kebangsaan, Malaysia.
- *Siti Nuramanina Abdul Shukor, BDS, MFDSRCS, DClinDent, National University of Malaysia: Universiti Kebangsaan, Malaysia.
- Chui Ling Goo, DDS, MDS, MFD RCS, M Pros RCS, National University of Malaysia: Universiti Kebangsaan, Malaysia.
Zitieren
APA
Tiew, E. C., Azis, N., Teh, L. A., Shukor, S., & Goo, C. L. (2024). An In Vitro Study of Retention and Marginal Adaptation of Endocrowns With Different Intracoronal Depths. Operative Dentistry. https://doi.org/10.2341/23-063-l
Vancouver
Tiew EC, Azis N, Teh LA, Shukor S, Goo CL. An In Vitro Study of Retention and Marginal Adaptation of Endocrowns With Different Intracoronal Depths. Operative Dentistry. 2024. doi:10.2341/23-063-l
BibTeX
@article{Tiew2024,
author = {Tiew, E C and Azis, Nmn and Teh, L A and Shukor, Sna and Goo, C L},
title = {An In Vitro Study of Retention and Marginal Adaptation of Endocrowns With Different Intracoronal Depths},
journal = {Operative Dentistry},
year = {2024},
doi = {10.2341/23-063-l}
}
EUVIMED