Fast Curing with High-power Curing Lights Affects Depth of Cure and Post-gel Shrinkage and Increases Temperature in Bulk-fill Composites
Operative Dentistry · 2023-01 · 48 (1) · 98-107
DOI: 10.2341/21-160-l ↗Kurz gefasst
Fachartikel in der Zeitschrift Operative Dentistry, 2023-01. Verfasst von N C Odum und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nicholas C Odum, BS, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA. Hauptthemen laut MEDLINE: Curing Lights, Dental, Light-Curing of Dental Adhesives. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Objectives
High-power LED curing lights and bulk-fill resin composites are intended to reduce chair time. This study investigated depth of cure, post-gel shrinkage (responsible for shrinkage stress), and heat generation in bulk-fill composites when cured according to minimum curing times recommended by manufacturers of curing lights and composites.
Methods
A regular LED curing light (Demi Ultra, 1350 mW/cm 2 , Kerr Dental) and two LED curing lights with high-power modes (VALO Grand, 3117 mW/cm 2 Xtra Power, Ultradent; and Bluephase PowerCure, 2435 mW/cm 2 Turbo and 3344 mW/cm 2 3sCure, Ivoclar Vivadent) were tested on three bulk-fill composites (Filtek One Bulk Fill, 3M Oral Care Solutions; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; Tetric Powerfill, Ivoclar Vivadent). Using minimum times recommended by manufacturers (3, 5, 6, 10, or 20 seconds), depth of cure was determined by Vickers hardness of specimens cured in a slot (n=10). Post-gel polymerization shrinkage was measured using a strain gauge (n=10) and temperature with a thermocouple (n=5). Results were analyzed using two- and one-way analysis of variance (ANOVA) followed by pairwise comparisons or Student-Newman-Keuls post hoc tests (α=0.05).
Results
Curing lights and curing protocols significantly affected depth of cure, post-gel shrinkage, and temperature rise (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Nicholas C Odum, BS, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
- Jason T Ross, BS, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
- Nechama S Citrin, DMD, MS, Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
- Daranee Tantbirojn, DDS, MS, PhD, Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
- *Antheunis Versluis, PhD, Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
Zitieren
APA
Odum, N. C., Ross, J. T., Citrin, N. S., Tantbirojn, D., & Versluis, A. (2023). Fast Curing with High-power Curing Lights Affects Depth of Cure and Post-gel Shrinkage and Increases Temperature in Bulk-fill Composites. Operative Dentistry, 48(1), 98-107. https://doi.org/10.2341/21-160-l
Vancouver
Odum NC, Ross JT, Citrin NS, Tantbirojn D, Versluis A. Fast Curing with High-power Curing Lights Affects Depth of Cure and Post-gel Shrinkage and Increases Temperature in Bulk-fill Composites. Operative Dentistry. 2023;48(1):98-107. doi:10.2341/21-160-l
BibTeX
@article{Odum2023,
author = {Odum, N C and Ross, J T and Citrin, N S and Tantbirojn, D and Versluis, A},
title = {Fast Curing with High-power Curing Lights Affects Depth of Cure and Post-gel Shrinkage and Increases Temperature in Bulk-fill Composites},
journal = {Operative Dentistry},
year = {2023},
volume = {48},
number = {1},
pages = {98--107},
doi = {10.2341/21-160-l}
}
EUVIMED