EUVIMEDEUVIMED entdecken
Vergleichsstudie

Effect of Two Different Ultrafast Curing Exposure Durations on the Surface Hardness of Bulk Fill Composite - An In-Vitro Study

Shekar Shobana, Anandavelu Sujareetha, Sundaresan Balagopal, Sarath Kumar, Sriganesh Angusamy, Sebatni Anisha

Indian Journal of Dental Research · 2023

DOI: 10.4103/ijdr.ijdr_5_23 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Indian Journal of Dental Research, 2023. Verfasst von Shekar Shobana und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Tamil Nadu, India. Hauptthemen laut MEDLINE: Composite Resins, Hardness, Materials Testing, Surface Properties. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The aim of the present study is to assess the microhardness of resin-based composites (RBCs) cured with ultrafast curing mode at two different exposure durations. Study Design: This is an experimental in-vitro study. Forty-five cylindrical composite specimens were prepared to a dimension of 5 mm height and 4 mm diameter. Curing was done using three different exposure modes and duration with dual mode LED curing light as follows: Group I: Ultrafast curing mode for 1 second at 2300 mW/cm 2 (n = 15); Group II: Ultrafast curing mode for 3 second at 2300 mW/cm 2 (n = 15) and Group III: Standard exposure mode for 20 second at 1000 mW/cm 2 (n = 15). Vicker’s microhardness measurement was done on both the curing and non-curing sides of the specimen using a motorised diamond-faced micro-indenter (Wilson Wolpwert, Germany) using a load of 50 gram and a dwell time of 30 second. Statistical Analysis: Kruskal Wallis ANOVA was used to test for difference between the three groups followed by Mann–Whitney U test for post-hoc analysis.

Results

The microhardness values of the composite cured with a conventional curing unit were significantly higher than the ultrafast cured specimens.

Conclusion

Low-intensity conventional curing lights were found to perform better than the high-intensity ultrafast curing units.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Composite ResinsHardnessMaterials TestingSurface PropertiesCuring Lights, DentalTime FactorsLight-Curing of Dental AdhesivesPolymerizationHumansDental Materials

Substanzen

Composite ResinsDental Materials

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Tamil Nadu, India.
  • Department of Conservative Dentistry and Endodontics, Madha Dental College and Hospital, Sikkarayapuram, Tamil Nadu, India.

Zitieren

APA

Shobana, S., Sujareetha, A., Balagopal, S., Kumar, S., Angusamy, S., & Anisha, S. (2023). Effect of Two Different Ultrafast Curing Exposure Durations on the Surface Hardness of Bulk Fill Composite - An In-Vitro Study. Indian Journal of Dental Research. https://doi.org/10.4103/ijdr.ijdr_5_23

Vancouver

Shobana S, Sujareetha A, Balagopal S, Kumar S, Angusamy S, Anisha S. Effect of Two Different Ultrafast Curing Exposure Durations on the Surface Hardness of Bulk Fill Composite - An In-Vitro Study. Indian Journal of Dental Research. 2023. doi:10.4103/ijdr.ijdr_5_23

BibTeX
@article{Shobana2023,
  author = {Shobana, Shekar and Sujareetha, Anandavelu and Balagopal, Sundaresan and Kumar, Sarath and Angusamy, Sriganesh and Anisha, Sebatni},
  title = {Effect of Two Different Ultrafast Curing Exposure Durations on the Surface Hardness of Bulk Fill Composite - An In-Vitro Study},
  journal = {Indian Journal of Dental Research},
  year = {2023},
  doi = {10.4103/ijdr.ijdr_5_23}
}
Kostenlos starten →