In vivo virtual investigation of the implant location for scaphoid fractures
Journal of Plastic Surgery and Hand Surgery · 03.08.2026 · 61 · 182-188
DOI: 10.2340/jphs.v61.46484 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Plastic Surgery and Hand Surgery, online erschienen am 03.08.2026. Verfasst von Ren-Guo Xie und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, Shanghai First People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China; Department of Hand …. Hauptthemen laut MEDLINE: Scaphoid Bone, Bone Screws, Fracture Fixation, Internal, Fractures, Bone. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Scaphoid fractures still have high rate of nonunion, mainly due to the tenuous blood supply and only primary bone healing. Rigid fixation facilitates this kind of bone healing and is considered as vital as protection of the blood supply. The optimal implant (screw) location should meet the requirements for researcher’s biomechanical findings on fracture stability. Materials and methods: Raw CT-scanned data of eight volunteers’ wrists were imported into Mimics. The 3D scaphoid was segmented out and calculated, then opened in Geomagic Studio. Four fracture planes (proximal, oblique waist, horizontal waist and distal) simulating common broken scaphoid were created. Mimicking scaphoid implants (screws), the longest, the sub-longest, and central and eccentric cylinders perpendicular to each fracture plane were created. Whole and inside-fragmental length, and the relative location of each cylinder were measured and analyzed.
Results
The longest (28.5 ± 1.6 mm) cylinder was significantly longer than the sub-longest (25.4 ± 1.4 mm). Several eccentric perpendicular cylinders (so short or cutting out of the scaphoid) couldn’t be created. Some proximal inside-fragmental lengths ranged from 3.0 to 5.1 mm. Several central perpendicular cylinders intersected with the longest one. Several central and eccentric perpendicular cylinders were outside of the proximal scaphoid non-contact region.
Conclusion
The results of this study showed that scaphoid fracture images from CT scan can be calculated and yield the optimal implant location.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Hand Surgery, Shanghai First People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China; Department of Hand Surgery, Rugaogang Hospital, Jiangsu, China. renguo.xie@gmail.com.
- Department of Hand Surgery, Rugaogang Hospital, Jiangsu, China.
Zitieren
APA
Xie, R. G., & Ji, D. S. (2026). In vivo virtual investigation of the implant location for scaphoid fractures. Journal of Plastic Surgery and Hand Surgery, 61, 182-188. https://doi.org/10.2340/jphs.v61.46484
Vancouver
Xie RG, Ji DS. In vivo virtual investigation of the implant location for scaphoid fractures. Journal of Plastic Surgery and Hand Surgery. 2026;61:182-188. doi:10.2340/jphs.v61.46484
BibTeX
@article{Xie2026,
author = {Xie, Ren-Guo and Ji, Dong-Shen},
title = {In vivo virtual investigation of the implant location for scaphoid fractures},
journal = {Journal of Plastic Surgery and Hand Surgery},
year = {2026},
volume = {61},
pages = {182--188},
doi = {10.2340/jphs.v61.46484}
}
EUVIMED