Fachartikel in der Zeitschrift Orthopaedic Surgery, 2025. Verfasst von Xingye Du und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Affiliated Jiangyin Hospital of Nantong University, Jiangyin, China. Hauptthemen laut MEDLINE: Bone Screws, Imaging, Three-Dimensional, Tomography, X-Ray Computed, Pelvic Bones. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Jiangyin Municipal Health Commission Project, Wuxi Municipal Health Commission Project.
Abstract (Originalsprache)
Objective
Lateral compression II (LC‐II) fractures, a common type of pelvic injury, often require closed reduction and percutaneous screw fixation due to posterior pelvic ring instability. However, existing methods fail to adequately account for the internal structure of the screw path and lack precise anatomical guidance, increasing surgical risks. This study utilized digital medical software to analyze the LC‐II screw path and entry parameters, providing the anatomical references.
Methods
This retrospective study enrolled 43 adult patients (21 males and 22 females) who underwent a complete computed tomography (CT) scan examination from February 2017 to February 2019. The digital three‐dimensional (3D) pelvic model was reconstructed, and the ideal LC‐II screw path was designed by the cross‐section method. The primary evaluation parameters included the screw path length ( D AP ), maximum diameter ( D max ), distances at narrow points ( D 1 and D 2), bone thickness parameters (OW1 and IW1; OW2 and IW2), and screw entry angles (∠ α , ∠ β , ∠ γ ).
Results
Of 43 patients, 42 successfully completed LC‐II screw path construction. Among 21 female patients, 5 (23.8%) could accommodate screws with a maximum diameter of < 6.5 mm. Compared with female patients, male patients exhibited significantly higher D AP , D max , D 2 , OW 1 , IW 1 , IW 1 /OW 1 , and IW 2 /OW 2 ( p < 0.05). The ∠ γ was significantly lower in male patients. Furthermore, digital 3D pelvic model observations revealed that LC‐II screws bone entry points in the anterior iliac region were all located posterior to the anterior inferior iliac spine (AIIS). The angles between the LC‐II screw and coronal plane were 48.06° in males and 45.10° in females, while the angles between the LC‐II screw and sagittal plane were 27.14° and 25.60°, respectively.
Conclusion
This study utilized digital medical software to construct the LC‐II screw path and analyze sex‐based differences, highlighting the importance of individualized preoperative path planning and providing essential anatomical evidence for the precise and safe percutaneous insertion of LC‐II screws.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Affiliated Jiangyin Hospital of Nantong University, Jiangyin, China.
ORCID-Profile: Xingye Du
Förderung
- Jiangyin Municipal Health Commission Project
- Wuxi Municipal Health Commission Project
Zitieren
APA
Du, X., Liu, Y., & Jiang, X. (2025). Anatomical Study of Lateral Compression II Screw Path and Entry Parameters Based on Three‐Dimensional CT Image Reconstruction Techniques. Orthopaedic Surgery. https://doi.org/10.1111/os.70011
Vancouver
Du X, Liu Y, Jiang X. Anatomical Study of Lateral Compression II Screw Path and Entry Parameters Based on Three‐Dimensional CT Image Reconstruction Techniques. Orthopaedic Surgery. 2025. doi:10.1111/os.70011
BibTeX
@article{Du2025,
author = {Du, Xingye and Liu, Yong and Jiang, Xuefeng},
title = {Anatomical Study of Lateral Compression II Screw Path and Entry Parameters Based on Three‐Dimensional CT Image Reconstruction Techniques},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.70011}
}
EUVIMED