Effect of maturation time and adhesive system on the shear bond strength and failure modes of Biodentine™ bonded with resin composite and glass ionomer cement
Biomaterial Investigations in Dentistry · 27.04.2026 · 13 · 323-331
DOI: 10.2340/biid.v13.45898 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomaterial Investigations in Dentistry, online erschienen am 27.04.2026. Verfasst von Wichida Chaweewannakorn und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pedodontics and Preventive Dentistry, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand. Die Arbeit nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
This study aimed (1) to compare the shear bond strength (SBS) and failure modes of Biodentine™ (BD) specimens bonded with resin composite (RC) or high-viscosity glass ionomer cement (HVGIC) at different maturation times and (2) to compare the SBS of BD bonded with RC using different adhesive systems. Materials and Methods: Part I: A total of 120 BD specimens were bonded with either RC or HVGIC (n = 60 each), then divided into four groups (n = 15 each) based on BD maturation time: 12 min, 24 h, 48 h, and 1 week. Part 2: A total of 45 BD specimens matured for 24 h were bonded with RC using 3 adhesives (n = 15 each): (1) Single Bond Universal (SU) with self-etched technique (SU-SE), (2) Adper Single Bond 2 adhesive with etch and rinse technique (AS-ER), and (3) SU adhesive with etch-and-rinse technique (SU-ER). All specimens underwent pH cycling and thermocycling. SBS was measured using a universal testing machine, and failure modes were examined under a stereomicroscope.
Results
BD bonded with RC showed significantly higher SBS than BD bonded with HVGIC at all BD maturation times (p < 0.05). No significant SBS differences were found within RC groups, except between the 24-h and 1-week. Cohesive failure predominated in RC specimens (70%), whereas adhesive failure prevailed in HVGIC specimens (71.7%). SU-ER had significantly higher SBS than SU-SE or AS-ER (p < 0.05).
Conclusion
BD bonded with RC demonstrated higher SBS than BD bonded with HVGIC. The failure mode in the RC group was predominantly cohesive, whereas in the HVGIC group, it was primarily adhesive. These findings support the clinical applicability of immediate definitive RC placement over BD using a methacryloyloxydecyl dihydrogen phosphate-containing adhesive with an etch-and-rinse strategy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pedodontics and Preventive Dentistry, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand.
- Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand.
- Department of Stomatology, Faculty of Dentistry, Srinakharinwirot University, Bangkok, Thailand.
ORCID-Profile: Wichida Chaweewannakorn, Kittichot Saetae, Achirawat Wattakul, Suprawee Ngamjantratip, Pathida Pornraksamanee, Nirada Dhanesuan, Narinee Chinajitphan, Kwanchanok Youcharoen
Zitieren
APA
Chaweewannakorn, W., Saetae, K., Wattakul, A., Ngamjantratip, S., Pornraksamanee, P., Dhanesuan, N., Chinajitphan, N., & Youcharoen, K. (2026). Effect of maturation time and adhesive system on the shear bond strength and failure modes of Biodentine™ bonded with resin composite and glass ionomer cement. Biomaterial Investigations in Dentistry, 13, 323-331. https://doi.org/10.2340/biid.v13.45898
Vancouver
Chaweewannakorn W, Saetae K, Wattakul A, Ngamjantratip S, Pornraksamanee P, Dhanesuan N, et al. Effect of maturation time and adhesive system on the shear bond strength and failure modes of Biodentine™ bonded with resin composite and glass ionomer cement. Biomaterial Investigations in Dentistry. 2026;13:323-331. doi:10.2340/biid.v13.45898
BibTeX
@article{Chaweewannakorn2026,
author = {Chaweewannakorn, Wichida and Saetae, Kittichot and Wattakul, Achirawat and Ngamjantratip, Suprawee and Pornraksamanee, Pathida and Dhanesuan, Nirada and Chinajitphan, Narinee and Youcharoen, Kwanchanok},
title = {Effect of maturation time and adhesive system on the shear bond strength and failure modes of Biodentine™ bonded with resin composite and glass ionomer cement},
journal = {Biomaterial Investigations in Dentistry},
year = {2026},
volume = {13},
pages = {323--331},
doi = {10.2340/biid.v13.45898}
}
EUVIMED