Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study
Acta Odontologica Scandinavica · 20.07.2026 · 85 · 469-475
DOI: 10.2340/aos.v85.46531 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Odontologica Scandinavica, online erschienen am 20.07.2026. Verfasst von Esra Balkanlıoğlu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey. Hauptthemen laut MEDLINE: Dental Instruments, Cone-Beam Computed Tomography, Ultrasonics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
This in vitro study compared the efficacy, dentin loss, and outcomes of ultrasonic, Masserann, and Broken Tool Remover Pen (BTR-Pen) techniques for removing fractured endodontic instruments using cone-beam computed tomography (CBCT) analysis. Materials and methods: Ninety extracted single-rooted teeth were randomly allocated into three groups (n = 30). ProTaper F2 instruments were intentionally fractured in the middle third of each canal, creating 3–4 mm fragments. Removal was performed using ultrasonic tips, Masserann trephine burs, or the BTR-Pen loop system. CBCT scans quantified dentin loss. Success rates, removal times, and complications were analyzed using one-way analysis of variance, Tukey honestly significant difference, chi-square, and likelihood-ratio chi-square tests (p < 0.05).
Results
Ultrasonic removal showed the highest success rate (90.0%), followed by BTR-Pen (86.7%) and Masserann (70.0%). Pairwise likelihood-ratio chi-square analysis showed lower success for Masserann than ultrasonic removal (p = 0.049). Masserann caused significantly greater canal volume increase (4.50 ± 0.50 mm³) than ultrasonic (0.75 ± 0.30 mm³) and BTR-Pen (0.93 ± 0.40 mm³) techniques (p < 0.001). Ultrasonic removal required the shortest time (110.0 ± 35.0 s), followed by BTR-Pen (213.4 ± 40.0 s) and Masserann (240.0 ± 50.0 s).
Conclusions
Ultrasonic and BTR-Pen techniques achieved high success with better dentin preservation than Masserann. When retrieval is indicated, techniques that maximize dentin preservation should be preferred to reduce the risk of root weakening and procedural complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Endodontics, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey.
- Department of Endodontics, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey. aliyekamalak@gmail.com.
ORCID-Profile: Esra Balkanlıoğlu, Aliye Kamalak, Berkcan Güner
Zitieren
APA
Balkanlıoğlu, E., Kamalak, A., & Güner, B. (2026). Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study. Acta Odontologica Scandinavica, 85, 469-475. https://doi.org/10.2340/aos.v85.46531
Vancouver
Balkanlıoğlu E, Kamalak A, Güner B. Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study. Acta Odontologica Scandinavica. 2026;85:469-475. doi:10.2340/aos.v85.46531
BibTeX
@article{Balkanlolu2026,
author = {Balkanlıoğlu, Esra and Kamalak, Aliye and Güner, Berkcan},
title = {Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study},
journal = {Acta Odontologica Scandinavica},
year = {2026},
volume = {85},
pages = {469--475},
doi = {10.2340/aos.v85.46531}
}
EUVIMED