EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study

Esra Balkanlıoğlu iD, Aliye Kamalak iD, Berkcan Güner iD

Acta Odontologica Scandinavica · 20.07.2026 · 85 · 469-475

DOI: 10.2340/aos.v85.46531 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Acta Odontologica Scandinavica, online erschienen am 20.07.2026. Verfasst von Esra Balkanlıoğlu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey. Hauptthemen laut MEDLINE: Dental Instruments, Cone-Beam Computed Tomography, Ultrasonics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This in vitro study compared the efficacy, dentin loss, and outcomes of ultrasonic, Masserann, and Broken Tool Remover Pen (BTR-Pen) techniques for removing fractured endodontic instruments using cone-beam computed tomography (CBCT) analysis. Materials and methods: Ninety extracted single-rooted teeth were randomly allocated into three groups (n = 30). ProTaper F2 instruments were intentionally fractured in the middle third of each canal, creating 3–4 mm fragments. Removal was performed using ultrasonic tips, Masserann trephine burs, or the BTR-Pen loop system. CBCT scans quantified dentin loss. Success rates, removal times, and complications were analyzed using one-way analysis of variance, Tukey honestly significant difference, chi-square, and likelihood-ratio chi-square tests (p < 0.05).

Results

Ultrasonic removal showed the highest success rate (90.0%), followed by BTR-Pen (86.7%) and Masserann (70.0%). Pairwise likelihood-ratio chi-square analysis showed lower success for Masserann than ultrasonic removal (p = 0.049). Masserann caused significantly greater canal volume increase (4.50 ± 0.50 mm³) than ultrasonic (0.75 ± 0.30 mm³) and BTR-Pen (0.93 ± 0.40 mm³) techniques (p < 0.001). Ultrasonic removal required the shortest time (110.0 ± 35.0 s), followed by BTR-Pen (213.4 ± 40.0 s) and Masserann (240.0 ± 50.0 s).

Conclusions

Ultrasonic and BTR-Pen techniques achieved high success with better dentin preservation than Masserann. When retrieval is indicated, techniques that maximize dentin preservation should be preferred to reduce the risk of root weakening and procedural complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental InstrumentsCone-Beam Computed TomographyUltrasonicsHumansIn Vitro TechniquesMicroscopy

Autor:innen und Institutionen

  • Department of Endodontics, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey.
  • Department of Endodontics, Kahramanmaras Sutcu Imam University, Kahramanmaras, Turkey. aliyekamalak@gmail.com.

ORCID-Profile: Esra Balkanlıoğlu, Aliye Kamalak, Berkcan Güner

Zitieren

APA

Balkanlıoğlu, E., Kamalak, A., & Güner, B. (2026). Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study. Acta Odontologica Scandinavica, 85, 469-475. https://doi.org/10.2340/aos.v85.46531

Vancouver

Balkanlıoğlu E, Kamalak A, Güner B. Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study. Acta Odontologica Scandinavica. 2026;85:469-475. doi:10.2340/aos.v85.46531

BibTeX
@article{Balkanlolu2026,
  author = {Balkanlıoğlu, Esra and Kamalak, Aliye and Güner, Berkcan},
  title = {Comparison of the ultrasonic, Masserann, and BTR-pen techniques for removing fractured instruments with dental microscope: a CBCT-based in vitro study},
  journal = {Acta Odontologica Scandinavica},
  year = {2026},
  volume = {85},
  pages = {469--475},
  doi = {10.2340/aos.v85.46531}
}
Kostenlos starten →