EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Cone-beam computed tomography evaluation of shaping ability of kedo-S square and fanta AF™ baby rotary files compared to manual K-files in root canal preparation of primary anterior teeth

Shaimaa S El-Desouky, Bassem N El Fahl, Ibrahim A Kabbash, Shimaa M Hadwa

Clinical Oral Investigations · 2024

DOI: 10.1007/s00784-024-05726-y ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Investigations, 2024. Verfasst von Shaimaa S El-Desouky und 3 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Dentistry, Preventive Dentistry Department, Faculty of Dentistry, Oral Health, Tanta University, Tanta, Egypt. shaimaaeldesouky@dent.tanta.…. Hauptthemen laut MEDLINE: Root Canal Preparation, Cone-Beam Computed Tomography, Tooth, Deciduous, Equipment Design. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tanta University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pediatric rotary file systems were developed to solve manual file limitations. With many systems available, it may be tricky to select the most appropriate one. Aim to assess & compare Kedo-S Square, Fanta-AF™-Baby rotary files with manual K-file concerning removed dentin amount, canal transportation, centric ability & root canal taper using CBCT in primary anterior teeth.

Design

Extracted Seventy-five upper primary anterior teeth with intact 2/3 root length were collected and divided into three groups based on root canal instrumentation, group-I: prepared using K-file, group-II: prepared using Kedo-S Square, and group-III: prepared using Fanta AF™ Baby file. The teeth were imaged with CBCT before & following canal instrumentation. Then, the removed dentin amount was calculated at each root-canal level. The Kruskal-Wallis test was utilized to statistically analyze study data.

Result

The difference among the three groups was highly statistically significant at cervical & apical thirds concerning dentin thickness changes on both mesial & distal sides following canal preparation with the least removed dentin in the Kedo-S Square group( P < 0.0001). Regarding transportation & centering ability, a non-significant difference between the three groups was found. 80% of the Fanta AF™ Baby group had good-tapered preparation compared to the Kedo-S Square (72%) and K-file (40%) groups( P < 0.05).

Conclusion

Kedo-S Square was preferable to Fanta-AF TM -Baby & manual K-files in primary root canal preparation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Root Canal PreparationCone-Beam Computed TomographyTooth, DeciduousEquipment DesignHumansIn Vitro TechniquesIncisorDental InstrumentsDental Pulp Cavity

Stichwörter der Autor:innen

Cone-beam computed tomographyFanta AF™ Baby fileKedo-S square fileManual K-filePrimary teethRoot canal treatment

Autor:innen und Institutionen

  • Pediatric Dentistry, Preventive Dentistry Department, Faculty of Dentistry, Oral Health, Tanta University, Tanta, Egypt. shaimaaeldesouky@dent.tanta.edu.eg.
  • Oral Medicine, Periodontology, Oral Diagnosis, and Radiology Department, Faculty of Dentistry, Tanta University, Tanta, Egypt.
  • Public Health & Community Medicine Department, Faculty of Medicine, Tanta University, Tanta, Egypt.
  • Pediatric Dentistry, Preventive Dentistry Department, Faculty of Dentistry, Oral Health, Tanta University, Tanta, Egypt.

Förderung

  • Tanta University

Zitieren

APA

El-Desouky, S. S., El Fahl, B. N., Kabbash, I. A., & Hadwa, S. M. (2024). Cone-beam computed tomography evaluation of shaping ability of kedo-S square and fanta AF™ baby rotary files compared to manual K-files in root canal preparation of primary anterior teeth. Clinical Oral Investigations. https://doi.org/10.1007/s00784-024-05726-y

Vancouver

El-Desouky SS, El Fahl BN, Kabbash IA, Hadwa SM. Cone-beam computed tomography evaluation of shaping ability of kedo-S square and fanta AF™ baby rotary files compared to manual K-files in root canal preparation of primary anterior teeth. Clinical Oral Investigations. 2024. doi:10.1007/s00784-024-05726-y

BibTeX
@article{ElDesouky2024,
  author = {El-Desouky, Shaimaa S and El Fahl, Bassem N and Kabbash, Ibrahim A and Hadwa, Shimaa M},
  title = {Cone-beam computed tomography evaluation of shaping ability of kedo-S square and fanta AF™ baby rotary files compared to manual K-files in root canal preparation of primary anterior teeth},
  journal = {Clinical Oral Investigations},
  year = {2024},
  doi = {10.1007/s00784-024-05726-y}
}
Kostenlos starten →