EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Frequency of safety signals from scientific reports, manufactures, registers, and other sources for a random selection of hip and knee prostheses

Yijun Ren iD, Lotje A Hoogervorst iD, Enrico G Caiani, Perla J Marang-van de Mheen, James A Smith, Alan G Fraser, Rob G H H Nelissen iD, Anne Lübbeke iD

Acta Orthopaedica · 2025

DOI: 10.2340/17453674.2025.44035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Orthopaedica, 2025. Verfasst von Yijun Ren und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano, Milan, Italy. Hauptthemen laut MEDLINE: Knee Prosthesis, Hip Prosthesis, Product Surveillance, Postmarketing, Arthroplasty, Replacement, Hip. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and purpose: The safety and performance of hip and knee prostheses can be assessed by analyzing peer-reviewed literature, registry reports, and safety notices published by national competent authorities/regulatory agencies, or manufacturers. The percentage of hip and knee prostheses with a safety signal published through any of these data sources is unknown. We aimed to assess the frequency of signals identified for a random sample of 10 hip stems, 10 hip cups, and 10 knee implants.

Methods

3 literature libraries were searched to find safety signals defined as information on patterns/occurrences that may alter the device’s benefit–risk profile, reported in peer-reviewed publications for the randomly selected implants. Annual registry reports from 5 national registries were examined to check whether any of the selected implants had outlier performance. The CORE-MD post-market surveillance (PMS) tool was used to collect all related safety notices from 13 competent authority/regulatory agency websites. Manufacturers’ websites were screened for any reported safety information.

Results

Safety signals were identified for 21 of the 30 randomly selected implants: 18 identified by registries, 7 by the CORE-MD PMS tool, and 8 based on literature, with 10 implants identified by multiple sources. There was no systematic pattern in timing of publication with a particular source publishing safety signals earlier than other sources.

Conclusion

70% of the randomly selected hip and knee prostheses had ≥ 1 safety signals published, with registries as the source for the majority. No single source identified all 21 implants with signals, which highlights the need for a comprehensive surveillance strategy to aggregate safety signals from multiple sources.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Knee ProsthesisHip ProsthesisProduct Surveillance, PostmarketingArthroplasty, Replacement, HipArthroplasty, Replacement, KneeHumansRegistriesProsthesis Design

Autor:innen und Institutionen

  • Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano, Milan, Italy.
  • Department of Orthopaedics, Leiden University Medical Center, Leiden, the Netherlands l.a.hoogervorst@lumc.nl.
  • Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano, Milan, Istituto Auxologico Italiano IRCCS, Milan, Italy.
  • Department of Orthopaedics, Leiden University Medical Center, Leiden; Safety & Security Science and Centre for Safety in Healthcare, Delft University of Technology, Delft, the Netherlands.
  • Botnar Research Centre and Centre for Statistics in Medicine, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford; 6 National Institute for Health Research Oxford…
  • Department of Cardiology, University Hospital of Wales, Heath Park, Cardiff, UK.

ORCID-Profile: Yijun Ren, Lotje A Hoogervorst, Rob G H H Nelissen, Anne Lübbeke

Zitieren

APA

Ren, Y., Hoogervorst, L. A., Caiani, E. G., Marang-van de Mheen, P. J., Smith, J. A., Fraser, A. G., Nelissen, R. G. H. H., & Lübbeke, A. (2025). Frequency of safety signals from scientific reports, manufactures, registers, and other sources for a random selection of hip and knee prostheses. Acta Orthopaedica. https://doi.org/10.2340/17453674.2025.44035

Vancouver

Ren Y, Hoogervorst LA, Caiani EG, Marang-van de Mheen PJ, Smith JA, Fraser AG, et al. Frequency of safety signals from scientific reports, manufactures, registers, and other sources for a random selection of hip and knee prostheses. Acta Orthopaedica. 2025. doi:10.2340/17453674.2025.44035

BibTeX
@article{Ren2025,
  author = {Ren, Yijun and Hoogervorst, Lotje A and Caiani, Enrico G and Marang-van de Mheen, Perla J and Smith, James A and Fraser, Alan G and Nelissen, Rob G H H and Lübbeke, Anne},
  title = {Frequency of safety signals from scientific reports, manufactures, registers, and other sources for a random selection of hip and knee prostheses},
  journal = {Acta Orthopaedica},
  year = {2025},
  doi = {10.2340/17453674.2025.44035}
}
Kostenlos starten →