EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validating Orthopaedic Data Evaluation Panel (ODEP) Ratings Across 9 Orthopaedic Registries

Lotje A Hoogervorst iD, Maartje M van Tilburg iD, Anne Lübbeke iD, Tim Wilton, Rob G H H Nelissen iD, Perla J Marang-van de Mheen iD

Journal of Bone and Joint Surgery · 2024

DOI: 10.2106/jbjs.23.00793 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Bone and Joint Surgery, 2024. Verfasst von Lotje A Hoogervorst und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands. Hauptthemen laut MEDLINE: Registries, Hip Prosthesis, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Orthopaedic Data Evaluation Panel (ODEP) ratings of total hip (TH) and total knee (TK) implants are informative for assessing implant performance. However, the validity of ODEP ratings across multiple registries is unknown. Therefore, we aimed to assess, across multiple registries, whether TH and TK implants with a higher ODEP rating (i.e., an A* rating) have lower cumulative revision risks (CRRs) than those with a lower ODEP rating (i.e., an A rating) and the extent to which A* and A-rated implants would be A*-rated on the basis of the pooled registries’ CRR.

Methods

Implant-specific CRRs at 3, 5, and 10 years that were reported by registries were matched to ODEP ratings on the basis of the implant name. A meta-analysis with random-effects models was utilized for pooling the CRRs. ODEP benchmark criteria were utilized to classify these pooled CRRs.

Results

A total of 313 TH cups (54%), 356 TH stems (58%), 218 TH cup-stem combinations (34%), and 68 TK implants (13%) with unique brand names reported by registries were matched to an ODEP rating. Given the low percentage that matched, TK implants were not further analyzed. ODEP-matched TH implants had lower CRRs than TH implants without an ODEP rating at all follow-up time points, although the difference for TH stems was not significant at 5 years. No overall differences in CRRs were found between A* and A-rated TH implants, with the exception of TH cup-stem combinations, which demonstrated a significantly lower CRR for A*A*-rated cup-stem combinations at the 3-year time point. Thirty-nine percent of A*-rated cups and 42% of A*-rated stems would receive an A* rating on the basis of the pooled registries’ CRR at 3 years; however, 24% of A-rated cups and 31% of A-rated stems would also receive an A* rating, with similar findings demonstrated at longer follow-up.

Conclusions

At all follow-up time points, ODEP-matched TH implants had lower CRRs than TH implants without an ODEP rating. Given that the performance of TH implants varied across countries, registries should first validate ODEP ratings with use of country-specific revision data to better guide implant selection in their country. Data source transparency and the use of revision data from multiple registries would strengthen the ODEP benchmarks. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RegistriesHip ProsthesisArthroplasty, Replacement, HipHumansReoperationProsthesis FailureArthroplasty, Replacement, KneeKnee ProsthesisProsthesis Design

Autor:innen und Institutionen

  • Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.
  • Department of Biomedical Data Sciences, Medical Decision Making, Leiden University Medical Center, Leiden, The Netherlands.
  • Division of Orthopaedic Surgery and Traumatology, Geneva University Hospitals, Geneva Switzerland.
  • University of Geneva, Geneva, Switzerland.
  • Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, United Kingdom.
  • Department of Orthopaedics, Derby Teaching Hospitals NHS Foundation Trust, Derby, United Kingdom.

ORCID-Profile: Lotje A Hoogervorst, Maartje M van Tilburg, Anne Lübbeke, Rob G H H Nelissen, Perla J Marang-van de Mheen

Zitieren

APA

Hoogervorst, L. A., van Tilburg, M. M., Lübbeke, A., Wilton, T., Nelissen, R. G. H. H., & Marang-van de Mheen, P. J. (2024). Validating Orthopaedic Data Evaluation Panel (ODEP) Ratings Across 9 Orthopaedic Registries. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.23.00793

Vancouver

Hoogervorst LA, van Tilburg MM, Lübbeke A, Wilton T, Nelissen RGHH, Marang-van de Mheen PJ. Validating Orthopaedic Data Evaluation Panel (ODEP) Ratings Across 9 Orthopaedic Registries. Journal of Bone and Joint Surgery. 2024. doi:10.2106/jbjs.23.00793

BibTeX
@article{Hoogervorst2024,
  author = {Hoogervorst, Lotje A and van Tilburg, Maartje M and Lübbeke, Anne and Wilton, Tim and Nelissen, Rob G H H and Marang-van de Mheen, Perla J},
  title = {Validating Orthopaedic Data Evaluation Panel (ODEP) Ratings Across 9 Orthopaedic Registries},
  journal = {Journal of Bone and Joint Surgery},
  year = {2024},
  doi = {10.2106/jbjs.23.00793}
}