Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications

Claudia Piona, Eleonora Maria Aiello, Erika Caiazza, Aditya Ravi, Antonella Soglia, Elisa Morotti, Giuseppe Riccardi, Claudio Maffeis

Diabetes Care · 16.11.2026

DOI: 10.2337/dc26-1717 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes Care, online erschienen am 16.11.2026. Verfasst von Claudia Piona und 7 weiteren Autor:innen. Gefördert von: European Research Executive Agency.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE This study aimed to evaluate the accuracy of continuous glucose monitoring (CGM)–derived glucose values versus venous plasma glucose values during oral glucose tolerance testing (OGTT) in youths with obesity, their effect on glycemic classification, and whether deconvolution-based reconstruction improves agreement. RESEARCH DESIGN AND METHODS Twenty-nine youths with obesity underwent OGTT while wearing a FreeStyle Libre 2 sensor. Raw CGM values were temporally aligned with venous plasma glucose values and used to reconstruct plasma profiles via a first-order plasma–interstitial kinetic model and inverse filtering. Accuracy, agreement, consensus error grid, and glycemic classification were compared with collected venous plasma glucose values. RESULTS Temporally aligned CGM-derived values showed limited agreement with collected venous plasma glucose values (mean absolute relative difference [MARD] 12.96%; 51.72% of values within ±10 mg/dL; 20.06% of values differing by >25 mg/dL) and caused classification shifts. After reconstruction, MARD decreased to 5.55%, the proportion of values within ±10 mg/dL increased to 75.86%, almost all values fell within consensus error grid zone A, and classification shifts were reduced. CONCLUSIONS Deconvolution-based CGM reconstruction may support plasma-referenced, less invasive OGTT-based dysglycemic assessment.

Förderung

  • European Research Executive Agency

Zitieren

APA

Piona, C., Aiello, E. M., Caiazza, E., Ravi, A., Soglia, A., Morotti, E., Riccardi, G., & Maffeis, C. (2026). Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications. Diabetes Care. https://doi.org/10.2337/dc26-1717

Vancouver

Piona C, Aiello EM, Caiazza E, Ravi A, Soglia A, Morotti E, et al. Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications. Diabetes Care. 2026. doi:10.2337/dc26-1717

BibTeX
@article{Piona2026,
  author = {Piona, Claudia and Aiello, Eleonora Maria and Caiazza, Erika and Ravi, Aditya and Soglia, Antonella and Morotti, Elisa and Riccardi, Giuseppe and Maffeis, Claudio},
  title = {Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications},
  journal = {Diabetes Care},
  year = {2026},
  doi = {10.2337/dc26-1717}
}
Kostenlos starten →