EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY-NC-ND 4.0

Perioperative use and accuracy of continuous glucose monitoring: A systematic review

Léa Carlier, Charles De Ponthaud, Sophie Jacqueminet, Franck Phan, Sébastien Gaujoux, Chloé Amouyal iD

Diabetes, Obesity and Metabolism · 2025-10 · 27 (10) · 5393-5408

DOI: 10.1111/dom.16583 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Diabetes, Obesity and Metabolism, online erschienen am 04.07.2025. Verfasst von Léa Carlier und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diabetology-Metabolism, Institute of Cardiometabolism and Nutrition (ICAN), Pitié-Salpêtrière Hospital, AP-HP, Paris, France. Hauptthemen laut MEDLINE: Blood Glucose, Perioperative Care, Blood Glucose Self-Monitoring, Glycemic Control. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Perioperative impairment of glycaemic control significantly increases the risk of major postoperative complications. The use of continuous glucose monitoring (CGM) has demonstrated benefits in glycaemic control, but its use in the perioperative period remains unclear. The aim is to present the state of the art in the use and accuracy of CGM in the perioperative setting. A systematic literature search of PubMed MEDLINE, EMBASE, COCHRANE LIBRARY and CLINICAL TRIAL from 2014 to 2025 was conducted on the perioperative use of CGM. Hybrid closed‐loop systems, total pancreatectomy with pancreatic islet transplantation or insulinoma resection were excluded to mitigate the risk of bias. Patients and sensors characteristics, time in range, postoperative outcomes and metrics accuracy were extracted. Forty studies were included, comprising 2397 patients, among studies including patients living with diabetes, 42.2% in median, primarily undergoing cardiothoracic (40%) and digestive (27.5%) surgeries, with sensors also used in the operating room (45%) and postoperatively in the intensive care unit (ICU) (57.9%). In overall studies, ICU, and intraoperative setting, the median Mean Absolute Relative Difference (MARD) was 14.2% (IQR 12.2–18.4), 12.9% (IQR 11.6–19.9), 14.2% (IQR 13.1–23.8), and the median Clarke Error Grid analysis, zones A + B, was 98.9% (IQR 97.9–99.2), 98.9% (IQR 98.1–99.3), 99.1% (IQR 97.3–100). CGM was non‐inferior to point‐of‐care glucose monitoring, with a trend towards improved hyperglycaemic control with fewer recurrent hypoglycaemic events in the majority of the studies. Half the studies reported technical challenges/interferences affecting CGM during surgery (due to: hypothermia, extracorporeal circulation, hyperhydration and subcutaneous tissue oedema, warming systems and electrical interference with monopolar or bipolar coagulation techniques), although accuracy typically recovered postoperatively. CGM seems to be a valuable tool in perioperative context, providing real‐time data, trends and alerts that enable better detection and management of hypoglycaemia and hyperglycaemia compared with conventional capillary. Its clinical interest remains to be proven by high quality randomized controlled trial especially regarding technical issues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucosePerioperative CareBlood Glucose Self-MonitoringGlycemic ControlDiabetes MellitusHumansHypoglycemiaPostoperative ComplicationsContinuous Glucose Monitoring

Stichwörter der Autor:innen

continuous glucose monitoringglycaemic controlperformance of sensorperioperative caresurgery

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Department of Diabetology-Metabolism, Institute of Cardiometabolism and Nutrition (ICAN), Pitié-Salpêtrière Hospital, AP-HP, Paris, France.
  • Sorbonne Université, Paris, France.
  • Department of General, Visceral, and Endocrine Surgery, Pitié-Salpêtrière Hospital, AP-HP, Paris, France.
  • Department of Hepato-Biliary and Pancreatic Surgery and Liver Transplantation, AP-HP, Pitié-Salpêtrière Hospital, Paris, France.

ORCID-Profile: Chloé Amouyal

Zitieren

APA

Carlier, L., De Ponthaud, C., Jacqueminet, S., Phan, F., Gaujoux, S., & Amouyal, C. (2025). Perioperative use and accuracy of continuous glucose monitoring: A systematic review. Diabetes, Obesity and Metabolism, 27(10), 5393-5408. https://doi.org/10.1111/dom.16583

Vancouver

Carlier L, De Ponthaud C, Jacqueminet S, Phan F, Gaujoux S, Amouyal C. Perioperative use and accuracy of continuous glucose monitoring: A systematic review. Diabetes, Obesity and Metabolism. 2025;27(10):5393-5408. doi:10.1111/dom.16583

BibTeX
@article{Carlier2025,
  author = {Carlier, Léa and De Ponthaud, Charles and Jacqueminet, Sophie and Phan, Franck and Gaujoux, Sébastien and Amouyal, Chloé},
  title = {Perioperative use and accuracy of continuous glucose monitoring: A systematic review},
  journal = {Diabetes, Obesity and Metabolism},
  year = {2025},
  volume = {27},
  number = {10},
  pages = {5393--5408},
  doi = {10.1111/dom.16583}
}
Kostenlos starten →