MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses
Diabetes Care · 2026
DOI: 10.2337/dc25-2124 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diabetes Care, 2026. Verfasst von Fang Niu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medtronic Diabetes, Northridge, CA. Hauptthemen laut MEDLINE: Insulin, Insulin Infusion Systems, Hypoglycemic Agents, Diabetes Mellitus, Type 1. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Medtronic Diabetes.
Abstract (Originalsprache)
OBJECTIVE To evaluate glycemic metrics and insulin delivery during real-world use of the MiniMed 780G (MM780G) system on days when users did not administer boluses. RESEARCH DESIGN AND METHODS Global CareLink personal data of consenting MM780G users (N = 369,467) uploaded from 2 January 2020 to 31 March 2025 were analyzed. Among these individuals, 54,553 users experienced ≥10 days without any user-initiated boluses. Evaluated key metrics included time in range (TIR; 70–180 mg/dL), time below range (TBR; <70 mg/dL), time above range (>180 mg/dL), the glucose management indicator (GMI), and total insulin delivered. These were analyzed for the overall population who did not initiate boluses and for those who used and did not use recommended optimal settings (ROS; defined as a 100 mg/dL glucose target and a 2-h active insulin time). Subgroup analyses were conducted by age (≤15 or >15 years) and diabetes type (type 1 or 2). RESULTS On days when boluses were missed, ROS users had a mean sensor glucose (SG) of 149.2 mg/dL, with mean TIR, TBR, and GMI of 76.3%, 0.8%, and 6.9%, respectively, whereas non-ROS users had a mean SG of 159.7 mg/dL with mean TIR, TBR, and GMI of 69.3%, 0.9%, and 7.1%, respectively. ROS use was associated with more individuals achieving consensus TIR, TBR, and GMI goals. CONCLUSIONS These data demonstrate effective glycemic control with the MM780G system on days when some users did not initiate boluses. A greater proportion of real-world users achieved glycemic goals when ROS were used.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Medtronic Diabetes, Northridge, CA.
ORCID-Profile: Robert A Vigersky, Jennifer J F McVean
Förderung
- Medtronic Diabetes
Zitieren
APA
Niu, F., Liu, M., Yovanovich, C., Vigersky, R. A., Shin, J. J., & McVean, J. J. F. (2026). MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses. Diabetes Care. https://doi.org/10.2337/dc25-2124
Vancouver
Niu F, Liu M, Yovanovich C, Vigersky RA, Shin JJ, McVean JJF. MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses. Diabetes Care. 2026. doi:10.2337/dc25-2124
BibTeX
@article{Niu2026,
author = {Niu, Fang and Liu, Margaret and Yovanovich, Caroline and Vigersky, Robert A and Shin, John J and McVean, Jennifer J F},
title = {MiniMed 780G Advanced Hybrid Closed-Loop System Use During Days Without User-Initiated Boluses},
journal = {Diabetes Care},
year = {2026},
doi = {10.2337/dc25-2124}
}
EUVIMED