Effects of switching from MiniMed ™ 640G to 770G on continuous glucose monitoring metrics and DTR ‐ QOL scores: An observational study of Japanese people with type 1 diabetes mellitus
Journal of Diabetes Investigation · 2025
DOI: 10.1111/jdi.14350 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Diabetes Investigation, 2025. Verfasst von Toshiki Kogai und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Metabolism & Endocrinology, Juntendo University Graduate School of Medicine, Tokyo, Japan. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Quality of Life, Blood Glucose Self-Monitoring, Blood Glucose. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Themen: Diabetes mellitus
Abstract (Originalsprache)
Aims/Introduction We evaluated the effect of the MiniMed™ 770G, an insulin pump using hybrid closed‐loop technology, on blood glucose management and quality of life in Japanese people with type 1 diabetes. Materials and Methods This was a 52‐week, prospective, observational study. Fifty Japanese people with type 1 diabetes switched from the MiniMed™ 640G to 770G, and we analyzed the continuous glucose monitoring data of 24 subjects who used auto mode throughout the study. We also analyzed the scores of the Diabetes Therapy‐Related Quality of Life questionnaire completed by 26 auto‐mode users before and after the treatment change. Results The baseline time in range 70–180 mg/dL was 67.3 (54.8–78.4)%, with a significant improvement beginning 8 weeks after the switch and lasting until 52 weeks. The baseline time below range
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Metabolism & Endocrinology, Juntendo University Graduate School of Medicine, Tokyo, Japan.
ORCID-Profile: Junko Sato, Hirotaka Watada
Zitieren
APA
Kogai, T., Sato, J., Yasuda, H., Ayame, T., Ozaki, A., Takagi, E., Koshibu, M., Nishida, Y., Ikeda, F., & Watada, H. (2025). Effects of switching from MiniMed ™ 640G to 770G on continuous glucose monitoring metrics and DTR ‐ QOL scores: An observational study of Japanese people with type 1 diabetes mellitus. Journal of Diabetes Investigation. https://doi.org/10.1111/jdi.14350
Vancouver
Kogai T, Sato J, Yasuda H, Ayame T, Ozaki A, Takagi E, et al. Effects of switching from MiniMed ™ 640G to 770G on continuous glucose monitoring metrics and DTR ‐ QOL scores: An observational study of Japanese people with type 1 diabetes mellitus. Journal of Diabetes Investigation. 2025. doi:10.1111/jdi.14350