EUVIMEDOdkrijte EUVIMED
Open access

Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation

Barbora Voglová Hagerf iD, Marek Protus iD, Lenka Nemetova, Milos Mraz iD, Eva Kieslichova iD, Eva Uchytilova iD, Veronika Indrova, Jan Lelito, Peter Girman iD, Martin Haluzík iD, Janka Franekova iD, Veronika Svirlochova and 3 more

Diabetes Care · 2024-06-01 · 47 (6) · 956-963

DOI: 10.2337/dc23-1663 ↗

At a glance

Journal article in Diabetes Care, published online on 2024-02-27. Written by Barbora Voglová Hagerf and 14 co-authors. Institution: Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic. Major MEDLINE topics: Blood Glucose, Critical Illness. Cited 42 times so far (Crossref); 38 references. The full text is freely available in PubMed Central. Funded by: National Institute for Research of Metabolic and Cardiovascular Diseases (Programme EXCELES, ID Project No. LX22NPO5104) - Funded by the European Union - Next…, Cooperatio Programme, section Medical Diagnostics and Basic Medical Sciences, Charles University, Prague, Czech Republic.

PovzetekSubjectsBibliografski podatkiCiteRelated studies

Abstract (original language)

OBJECTIVE Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.

Subjects

MeSH terms (MEDLINE)

Blood GlucoseCritical IllnessHumansMaleMiddle AgedFemaleAgedAbdomenOrgan TransplantationFeasibility StudiesAdultMonitoring, PhysiologicContinuous Glucose Monitoring

Substances

Blood Glucose

Authors and institutions

  • Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
  • First Faculty of Medicine, Charles University, Prague, Czech Republic.
  • Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
  • Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
  • Third Faculty of Medicine, Charles University, Prague, Czech Republic.
  • Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA.

ORCID profiles: Barbora Voglová Hagerf, Marek Protus, Milos Mraz, Eva Kieslichova, Eva Uchytilova, Peter Girman, Martin Haluzík, Janka Franekova, David C Klonoff, Michael A Kohn, Antonin Jabor

Funding

  • National Institute for Research of Metabolic and Cardiovascular Diseases (Programme EXCELES, ID Project No. LX22NPO5104) - Funded by the European Union - Next…
  • Cooperatio Programme, section Medical Diagnostics and Basic Medical Sciences, Charles University, Prague, Czech Republic

Cite

APA

Voglová Hagerf, B., Protus, M., Nemetova, L., Mraz, M., Kieslichova, E., Uchytilova, E., Indrova, V., Lelito, J., Girman, P., Haluzík, M., Franekova, J., Svirlochova, V., Klonoff, D. C., Kohn, M. A., & Jabor, A. (2024). Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation. Diabetes Care, 47(6), 956-963. https://doi.org/10.2337/dc23-1663

Vancouver

Voglová Hagerf B, Protus M, Nemetova L, Mraz M, Kieslichova E, Uchytilova E, et al. Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation. Diabetes Care. 2024;47(6):956-963. doi:10.2337/dc23-1663

BibTeX
@article{VoglovHagerf2024,
  author = {Voglová Hagerf, Barbora and Protus, Marek and Nemetova, Lenka and Mraz, Milos and Kieslichova, Eva and Uchytilova, Eva and Indrova, Veronika and Lelito, Jan and Girman, Peter and Haluzík, Martin and Franekova, Janka and Svirlochova, Veronika and Klonoff, David C and Kohn, Michael A and Jabor, Antonin},
  title = {Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation},
  journal = {Diabetes Care},
  year = {2024},
  volume = {47},
  number = {6},
  pages = {956--963},
  doi = {10.2337/dc23-1663}
}
Start for free →