Safety and Efficacy of the Omnipod 5 Automated Insulin Delivery System in Adults With Type 2 Diabetes: From Injections to Hybrid Closed-Loop Therapy
Diabetes Care · 2023
DOI: 10.2337/dc22-1915 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Diabetes Care, 2023. Verfasst von Georgia M Davis und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Emory University, Atlanta, GA. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2. Die Arbeit wurde bisher 66-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, Insulet Corporation.
Themen: Diabetes mellitus
Abstract (Originalsprache)
OBJECTIVE Automated insulin delivery (AID) has rarely been studied in adults with type 2 diabetes. We tested the feasibility of using AID for type 2 diabetes with the Omnipod 5 System in a multicenter outpatient trial. RESEARCH DESIGN AND METHODS Participants previously were using either basal-only or basal-bolus insulin injections, with or without the use of a continuous glucose monitor (CGM), and had a baseline HbA1c ≥8% (≥64 mmol/mol). Participants completed 2 weeks of CGM sensor data collection (blinded for those not previously using CGM) with their standard therapy (ST), then transitioned to 8 weeks of AID. Participants who previously used basal-only injections used the AID system in manual mode for 2 weeks before starting AID. Antihyperglycemic agents were continued at clinician discretion. Primary safety outcomes were percentage of time with sensor glucose ≥250 mg/dL and <54 mg/dL during AID. Additional outcomes included HbA1c and time in target range (TIR) (70–180 mg/dL). RESULTS Participants (N = 24) had a mean (± SD) age of 61 ± 8 years, baseline HbA1c of 9.4% ± 0.9% (79 ± 10 mmol/mol), and diabetes duration of 19 ± 9 years. Percentage of time with sensor glucose ≥250 mg/dL decreased with AID by 16.9% ± 16.2% (P < 0.0001), whereas percentage of time at <54 mg/dL remained low during both ST and AID (median [interquartile range] 0.0% [0.00%, 0.06%] vs. 0.00% [0.00%, 0.03%]; P = 0.4543). HbA1c (± SD) decreased by 1.3% ± 0.7% (14 ± 8 mmol/mol; P < 0.0001) and TIR increased by 21.9% ± 15.2% (P < 0.0001) without a significant change in total daily insulin or BMI with AID. CONCLUSIONS Findings from this feasibility trial of AID in adults with type 2 diabetes with suboptimal glycemic outcomes justify further evaluation of this technology in this population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Medicine, Emory University, Atlanta, GA.
- Keck School of Medicine of the University of Southern California, Los Angeles, CA.
- Atlanta Diabetes Associates, Atlanta, GA.
- International Diabetes Center, Park Nicollet, HealthPartners, Minneapolis, MN.
- Insulet Corporation, Acton, MA.
ORCID-Profile: Lauren M Huyett, Trang T Ly
Förderung
- NIDDK NIH HHS
- Insulet Corporation
Zitieren
APA
Davis, G. M., Peters, A. L., Bode, B. W., Carlson, A. L., Dumais, B., Vienneau, T. E., Huyett, L. M., & Ly, T. T. (2023). Safety and Efficacy of the Omnipod 5 Automated Insulin Delivery System in Adults With Type 2 Diabetes: From Injections to Hybrid Closed-Loop Therapy. Diabetes Care. https://doi.org/10.2337/dc22-1915
Vancouver
Davis GM, Peters AL, Bode BW, Carlson AL, Dumais B, Vienneau TE, et al. Safety and Efficacy of the Omnipod 5 Automated Insulin Delivery System in Adults With Type 2 Diabetes: From Injections to Hybrid Closed-Loop Therapy. Diabetes Care. 2023. doi:10.2337/dc22-1915
BibTeX
@article{Davis2023,
author = {Davis, Georgia M and Peters, Anne L and Bode, Bruce W and Carlson, Anders L and Dumais, Bonnie and Vienneau, Todd E and Huyett, Lauren M and Ly, Trang T},
title = {Safety and Efficacy of the Omnipod 5 Automated Insulin Delivery System in Adults With Type 2 Diabetes: From Injections to Hybrid Closed-Loop Therapy},
journal = {Diabetes Care},
year = {2023},
doi = {10.2337/dc22-1915}
}
EUVIMED