1936-P: Cost Utility of Real-Time Continuous Glucose Monitoring (RT-CGM) vs. Self-Monitoring of Blood Glucose (SMBG) in People with Type 2 Diabetes Not on Insulin Therapy (T2D NIT) in the USA
Diabetes · 05.06.2026 · 75 (Supplement_1)
DOI: 10.2337/db26-1936-p ↗Kurz gefasst
Fachartikel in der Zeitschrift Diabetes, erschienen am 05.06.2026. Verfasst von SABRINA ILHAM und 1 weiteren Autor:innen.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Introduction and Objective: RT-CGM improved glycemic outcomes in people with T2D NIT in RCTs and real-world studies. However, it is unknown if RT-CGM would be a cost-effective strategy in T2D NIT from a commercial payer perspective in the USA. We conducted a cost-utility analysis (CUA) of RT-CGM compared to SMBG for T2D NIT from a US commercial payer perspective.
Methods
A 50-year analysis with a 3% annual discount was conducted using the IQVIA Core Diabetes Model. Key baseline characteristics and clinical efficacy for RT-CGM were sourced from Cox, et al. (PMID 33094208) and for SMBG from McIntosh, et al. (PMID 21686299). HbA1c reductions in the RT-CGM and SMBG arms were -1.1% and -0.25%, respectively. Escalation to basal insulin and subsequently to bolus insulin was modeled when HbA1c exceeded 8.5%. After insulin initiation, severe hypoglycemic event (SHE) and diabetic ketoacidosis (DKA) rates were modeled based on a large retrospective study by Karter et al. (PMID 34077502). All cost data were sourced from previously published CUAs.
Results
RT-CGM use was associated with an incremental quality adjusted life year (QALY) gain of 0.548 and incremental cost of $18,810 resulting in an incremental cost-utility ratio (ICUR) of $34,299/QALY. The ICUR is below the commonly cited willingness to pay threshold in the USA of $50,000/QALY. RT-CGM users are expected to incur lifetime savings of $19,258 per patient due to reductions in SHE, DKA, and micro- and macrovascular complications.
Conclusion
From a commercial payer perspective, RT-CGM demonstrates meaningful cost-utility in the T2D NIT population. Disclosure S. Ilham: Employee; Current; Dexcom, Inc. G. Norman: Employee; Current; Dexcom, Inc. Stock/Shareholder; Current; Dexcom, Inc.
Zitieren
APA
ILHAM, S., & NORMAN, G. (2026). 1936-P: Cost Utility of Real-Time Continuous Glucose Monitoring (RT-CGM) vs. Self-Monitoring of Blood Glucose (SMBG) in People with Type 2 Diabetes Not on Insulin Therapy (T2D NIT) in the USA. Diabetes, 75(Supplement_1). https://doi.org/10.2337/db26-1936-p
Vancouver
ILHAM S, NORMAN G. 1936-P: Cost Utility of Real-Time Continuous Glucose Monitoring (RT-CGM) vs. Self-Monitoring of Blood Glucose (SMBG) in People with Type 2 Diabetes Not on Insulin Therapy (T2D NIT) in the USA. Diabetes. 2026;75(Supplement_1). doi:10.2337/db26-1936-p
BibTeX
@article{ILHAM2026,
author = {ILHAM, SABRINA and NORMAN, GREG},
title = {1936-P: Cost Utility of Real-Time Continuous Glucose Monitoring (RT-CGM) vs. Self-Monitoring of Blood Glucose (SMBG) in People with Type 2 Diabetes Not on Insulin Therapy (T2D NIT) in the USA},
journal = {Diabetes},
year = {2026},
volume = {75},
number = {Supplement_1},
doi = {10.2337/db26-1936-p}
}
EUVIMED