EUVIMEDEUVIMED entdecken
Crossref

Effects of scan body splinting material types and heights on scanning accuracy and duration

Selin Atay, Ayşegül Kurt, Onur Doğan Dağ, Ahmet İlter Atay

Journal of Oral Science · 2026 · 68 (3) · 129-134

DOI: 10.2334/josnusd.25-0383 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Oral Science, 2026. Verfasst von Selin Atay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Trakya University. Hauptthemen laut MEDLINE: Splints. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to evaluate the effects of scan body splinting material types and heights on scanning accuracy and duration for a completely edentulous mandible. METHODS: Scan bodies on multi-unit abutments were splinted at heights of 2 mm and 6 mm using orthodontic elastic ligatures (OELs) and three-dimensionally printed attachments (3D-As). Forty scans were obtained (n = 10 per combination) and analyzed with Geomagic Control X software. The Shapiro-Wilk test was used to assess normality, and nonparametric data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (P 0.05). Linear deviation did not differ significantly overall (P = 0.062), but lower values were observed in OEL groups (P = 0.018). CONCLUSION: Splint height and material type significantly influence scanning time. The potential impact of splinting material type and height on accuracy should be carefully considered when planning digital impression protocols.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SplintsHumansTime Factors

Stichwörter der Autor:innen

all-on-fourdigital impressionscanning accuracyscanning timesplinting materials

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry, Trakya University.
  • Oral Implantology Program, Institute of Graduate Studies in Health Sciences, Istanbul University.

Zitieren

APA

Atay, S., Kurt, A., Dağ, O. D., & Atay, A. İ. (2026). Effects of scan body splinting material types and heights on scanning accuracy and duration. Journal of Oral Science, 68(3), 129-134. https://doi.org/10.2334/josnusd.25-0383

Vancouver

Atay S, Kurt A, Dağ OD, Atay Aİ. Effects of scan body splinting material types and heights on scanning accuracy and duration. Journal of Oral Science. 2026;68(3):129-134. doi:10.2334/josnusd.25-0383

BibTeX
@article{Atay2026,
  author = {Atay, Selin and Kurt, Ayşegül and Dağ, Onur Doğan and Atay, Ahmet İlter},
  title = {Effects of scan body splinting material types and heights on scanning accuracy and duration},
  journal = {Journal of Oral Science},
  year = {2026},
  volume = {68},
  number = {3},
  pages = {129--134},
  doi = {10.2334/josnusd.25-0383}
}
Kostenlos starten →