Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers
The Angle Orthodontist · 2024
DOI: 10.2319/120823-812.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Angle Orthodontist, 2024. Verfasst von Tarek ElShebiny und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Orthodontic Retainers, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
To evaluate the impact of printer technology and print orientation on the accuracy of directly printed retainers. Materials and Methods Digital retainers were printed with two different printing technologies: digital light processing (DLP) and stereolithography (SLA), using two different orientations: 0° and 90°. After printing, the retainers (n = 40) were scanned using cone-beam computed tomography. The DICOM files were then converted into standard tessellation language (STL) files. Comparison of the printed retainers with a master file was done by superimposition using a three-dimensional (3D) best-fit tool in Geomagic software. A ±0.25 mm tolerance was set to detect differences between the superimposed files. Statistical analysis was conducted (Kruskal-Wallis and Wilcoxon-Mann-Whitney tests, with Bonferroni correction).
Results
The lowest median average deviation was observed for the DLP horizontally printed models (median, [interquartile range (IQR)] = 0.01 mm, [−0.01, 0.02]) followed by the SLA horizontally printed retainers (median, [IQR] = 0.05 mm, [0.03, 0.07]). The highest median inside the tolerance levels ratio was observed for the horizontally SLA printed retainers (median, [IQR] = 78.9%, [74.4, 82.4%]) followed by the horizontally DLP printed retainers (median, [IQR] = 78.2%, [74.5, 80.7%]).
Conclusions
Both technologies (DLP and SLA) showed 3D printed results compatible with orthodontic clinical needs. Printing orientation was more important than printer type regarding its accuracy. Additional studies are needed to evaluate the accuracy of direct printed appliances clinically.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
ElShebiny, T., Menezes, L. M., Matthaios, S., Tsolakis, I. A., & Palomo, J. M. (2024). Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers. The Angle Orthodontist. https://doi.org/10.2319/120823-812.1
Vancouver
ElShebiny T, Menezes LM, Matthaios S, Tsolakis IA, Palomo JM. Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers. The Angle Orthodontist. 2024. doi:10.2319/120823-812.1
BibTeX
@article{ElShebiny2024,
author = {ElShebiny, Tarek and Menezes, Luciane Macedo de and Matthaios, Stefanos and Tsolakis, Ioannis A and Palomo, Juan Martin},
title = {Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers},
journal = {The Angle Orthodontist},
year = {2024},
doi = {10.2319/120823-812.1}
}
EUVIMED