EUVIMEDEUVIMED entdecken
Open Access

Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers

Tarek ElShebiny, Luciane Macedo de Menezes, Stefanos Matthaios, Ioannis A Tsolakis, Juan Martin Palomo

The Angle Orthodontist · 2024

DOI: 10.2319/120823-812.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Angle Orthodontist, 2024. Verfasst von Tarek ElShebiny und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Orthodontic Retainers, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the impact of printer technology and print orientation on the accuracy of directly printed retainers. Materials and Methods Digital retainers were printed with two different printing technologies: digital light processing (DLP) and stereolithography (SLA), using two different orientations: 0° and 90°. After printing, the retainers (n = 40) were scanned using cone-beam computed tomography. The DICOM files were then converted into standard tessellation language (STL) files. Comparison of the printed retainers with a master file was done by superimposition using a three-dimensional (3D) best-fit tool in Geomagic software. A ±0.25 mm tolerance was set to detect differences between the superimposed files. Statistical analysis was conducted (Kruskal-Wallis and Wilcoxon-Mann-Whitney tests, with Bonferroni correction).

Results

The lowest median average deviation was observed for the DLP horizontally printed models (median, [interquartile range (IQR)] = 0.01 mm, [−0.01, 0.02]) followed by the SLA horizontally printed retainers (median, [IQR] = 0.05 mm, [0.03, 0.07]). The highest median inside the tolerance levels ratio was observed for the horizontally SLA printed retainers (median, [IQR] = 78.9%, [74.4, 82.4%]) followed by the horizontally DLP printed retainers (median, [IQR] = 78.2%, [74.5, 80.7%]).

Conclusions

Both technologies (DLP and SLA) showed 3D printed results compatible with orthodontic clinical needs. Printing orientation was more important than printer type regarding its accuracy. Additional studies are needed to evaluate the accuracy of direct printed appliances clinically.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalOrthodontic RetainersCone-Beam Computed TomographyHumansStereolithographyOrthodontic Appliance DesignComputer-Aided Design

Stichwörter der Autor:innen

3D printingAccuracyDigital orthodonticsOrthodontics

Zitieren

APA

ElShebiny, T., Menezes, L. M., Matthaios, S., Tsolakis, I. A., & Palomo, J. M. (2024). Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers. The Angle Orthodontist. https://doi.org/10.2319/120823-812.1

Vancouver

ElShebiny T, Menezes LM, Matthaios S, Tsolakis IA, Palomo JM. Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers. The Angle Orthodontist. 2024. doi:10.2319/120823-812.1

BibTeX
@article{ElShebiny2024,
  author = {ElShebiny, Tarek and Menezes, Luciane Macedo de and Matthaios, Stefanos and Tsolakis, Ioannis A and Palomo, Juan Martin},
  title = {Effect of printing technology and orientation on the accuracy of three-dimensional printed retainers},
  journal = {The Angle Orthodontist},
  year = {2024},
  doi = {10.2319/120823-812.1}
}
Kostenlos starten →