EUVIMEDEUVIMED entdecken
Crossref

Error analysis of stages involved in CBCT-guided implant placement with surgical guides when different printing technologies are used

Brandon Yeager, Gülce Çakmak, Fengyun Zheng, William Michael Johnston, Burak Yilmaz

The Journal of Prosthetic Dentistry · 2024-11 · 132 (5) · 995-1004

DOI: 10.1016/j.prosdent.2022.11.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-11. Verfasst von Brandon Yeager und 4 weiteren Autor:innen. Beteiligte Einrichtung: Former Graduate Program Resident, Division of Restorative and Prosthetic Dentistry, Advanced Prosthodontics, College of Dentistry, The Ohio State Uni…. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Surgery, Computer-Assisted, Cone-Beam Computed Tomography, Dental Implantation, Endosseous. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Digital light processing (DLP), continuous liquid interface printing (CLIP), and stereolithography (SLA) technologies enable 3-dimensional (3D) printing of surgical guides. However, how their accuracy compares and how accuracy may affect subsequent steps in guided surgery is unclear. PURPOSE: The purpose of this in vitro study was to investigate the fabrication and seating accuracy of surgical guides printed by using DLP, SLA, and CLIP technologies and evaluate the positional deviation of the osteotomy site and placed implant compared with the digital implant plan. MATERIAL AND METHODS: Twenty-one polyurethane models were divided into 3 groups and used to plan implants and design surgical guides. The guides were fabricated by using DLP, SLA, or CLIP 3D printers (n=7) and scanned, and the scan file was compared with the digital design file to analyze the fabrication accuracy at the intaglio and overall external surfaces using root mean square (RMS) values. The triple scan protocol was used to evaluate the seating accuracy of the guides on their respective models. Osteotomies were prepared on models by using the guides followed by a microcomputed tomography image of each osteotomy. The implants were placed through the guides, the scan bodies were tightened to implants, and the models were scanned to obtain the images of placed implant position. Osteotomy and placed implant images were used to calculate the entry point, apex, and long axis deviations from the planned implant position with a software program. A 2-way repeated-measures ANOVA of the RMS data was used to analyze printing and seating trueness, and homogeneity of variance analyses were used at each surface for precision. A 3-way repeated-measures ANOVA was used to analyze distance deviations over the stages (osteotomy and final implant) and locations studied, and a 2-way repeated-measures ANOVA was used for angular deviations. Homogeneity of variance analyses were performed for precision (α=.05). RESULTS: The 3D printer type significantly affected the trueness of the guide at the intaglio surface (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalSurgery, Computer-AssistedCone-Beam Computed TomographyDental Implantation, EndosseousHumansOsteotomyStereolithographyIn Vitro TechniquesComputer-Aided Design

Autor:innen und Institutionen

  • Former Graduate Program Resident, Division of Restorative and Prosthetic Dentistry, Advanced Prosthodontics, College of Dentistry, The Ohio State University, Columbus, Ohio; Private Practice, Upper Arlington, Ohio. Elec…
  • Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Clinical Associate Professor, Department of Restorative Sciences, Advanced Education Program in Prosthodontics, University of Minnesota School of Dentistry, Minneapolis, Minn.
  • Professor Emeritus, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.
  • Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric D…

Zitieren

APA

Yeager, B., Çakmak, G., Zheng, F., Johnston, W. M., & Yilmaz, B. (2024). Error analysis of stages involved in CBCT-guided implant placement with surgical guides when different printing technologies are used. The Journal of Prosthetic Dentistry, 132(5), 995-1004. https://doi.org/10.1016/j.prosdent.2022.11.018

Vancouver

Yeager B, Çakmak G, Zheng F, Johnston WM, Yilmaz B. Error analysis of stages involved in CBCT-guided implant placement with surgical guides when different printing technologies are used. The Journal of Prosthetic Dentistry. 2024;132(5):995-1004. doi:10.1016/j.prosdent.2022.11.018

BibTeX
@article{Yeager2024,
  author = {Yeager, Brandon and Çakmak, Gülce and Zheng, Fengyun and Johnston, William Michael and Yilmaz, Burak},
  title = {Error analysis of stages involved in CBCT-guided implant placement with surgical guides when different printing technologies are used},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  volume = {132},
  number = {5},
  pages = {995--1004},
  doi = {10.1016/j.prosdent.2022.11.018}
}
Kostenlos starten →