EUVIMEDEUVIMED entdecken
Crossref

Biomechanical impact of beveling design on extrusion of a maxillary canine and a maxillary first molar: an in vitro and finite element analysis study

Flavio Traversa, Pascal Vollenweider, Damiano Salvatori, Eren Korunmuş

The Angle Orthodontist · 18.06.2026

DOI: 10.2319/100525-832.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Angle Orthodontist, erschienen am 18.06.2026. Verfasst von Flavio Traversa und 3 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To investigate the effect of beveling side (apical vs occlusal) on the extrusive biomechanics of clear aligners compared to unbeveled attachments when tracking issues occur. Materials and Methods An in vitro Orthodontic Force Simulator (OFS) was used to simulate extrusion of a maxillary canine and first molar. Three attachment designs (beveled apical, beveled occlusal, and conventional rectangular) were digitally designed on the target teeth and directly milled in zirconia material. Aligners were thermoformed for each design and target tooth. The tooth-aligner mismatch was created on the target tooth up to 1.0 mm to simulate the tracking issue. Finite Element Analysis (FEA) was conducted to simulate the OFS experiment and analyze stress distribution and deformation.

Results

The attachment designs yielded significant differences in extrusion forces and bucco-palatal moments on both teeth. Beveled apical attachments consistently produced the lowest forces and moments, especially as displacement increased. This was attributed to a sliding motion of the aligner along the tooth movement path, mitigating the negative effects of tracking errors. Rectangular and beveled occlusal attachments, while offering strong initial engagement, resulted in higher stress concentrations and variability in force delivery as the simulated aligner-tooth mismatch grew.

Conclusions

The beveled apical design provides more predictable and consistent extrusion forces, reducing unwanted side effects, particularly for large movements and high risk of tracking issues.

Schlagwörter

Stichwörter der Autor:innen

AttachmentsBevelingClear alignersExtrusionFEAIn vitro study

Zitieren

APA

Traversa, F., Vollenweider, P., Salvatori, D., & Korunmuş, E. (2026). Biomechanical impact of beveling design on extrusion of a maxillary canine and a maxillary first molar: an in vitro and finite element analysis study. The Angle Orthodontist. https://doi.org/10.2319/100525-832.1

Vancouver

Traversa F, Vollenweider P, Salvatori D, Korunmuş E. Biomechanical impact of beveling design on extrusion of a maxillary canine and a maxillary first molar: an in vitro and finite element analysis study. The Angle Orthodontist. 2026. doi:10.2319/100525-832.1

BibTeX
@article{Traversa2026,
  author = {Traversa, Flavio and Vollenweider, Pascal and Salvatori, Damiano and Korunmuş, Eren},
  title = {Biomechanical impact of beveling design on extrusion of a maxillary canine and a maxillary first molar: an in vitro and finite element analysis study},
  journal = {The Angle Orthodontist},
  year = {2026},
  doi = {10.2319/100525-832.1}
}
Kostenlos starten →