Evaluation of wear amounts of different composite resin attachments used in clear aligner treatment over a 6-month period: a retrospective study
The Angle Orthodontist · 2026-05 · 96 (3) · 318-325
DOI: 10.2319/040925-281.1 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Angle Orthodontist, 2026-05. Verfasst von Cenk Ahmet Akcan und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Composite Resins, Orthodontic Appliances, Removable, Dental Restoration Wear, Tooth Movement Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
To compare surface wear among three different attachment composite resins over a 6-month follow-up period. Materials and Methods Intraoral scanning was performed on 28 participants immediately after initial bonding of attachments (T0), and at 1 (T1), 3 (T2), and 6 months (T3) after starting aligner treatment. In Group 1 (N = 154 attachments), Tokuyama Estelite Universal Flow; in Group 2 (N = 166 attachments), Filtek Z350 XT Universal Restorative; and in Group 3 (N = 161 attachments), G-ænial Universal Injectable resins were used for bonding the attachments. The surface wear depth on attachments was measured using superimposed digitized models. Kruskal-Wallis and Friedman tests were used with a significance set at 5%.
Results
As treatment progressed, surface wear increased significantly in all groups ( P < .001). The wear amount for Group 3 was significantly greater than that for Groups 1 and 2 at the 3-month period ( P < .001). Regarding T0–T3 surface wear, Group 2 (0.03 mm) and Group 3 (0.0609 mm) exhibited significantly greater wear than Group 1 (0.0243 mm; P = .024 and P < .001). Surface wear was also significantly greater in Group 3 than in Group 2 ( P < .001). No significant difference was observed in T3–T0 wear values between conventional and optimized attachments within each group.
Conclusions
The wear of orthodontic attachments was greatly influenced by the type of composite resin. During the third and sixth months of the clinical period, G-ænial Universal Injectable resin demonstrated significantly greater surface wear than other resins. After 6 months, Tokuyama Estelite Universal Flow displayed the least surface wear.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Zitieren
APA
Akcan, C. A., Aksoz, G., Gorucu-Coskuner, H., Akarsu-Guven, B., & Atik, E. (2026). Evaluation of wear amounts of different composite resin attachments used in clear aligner treatment over a 6-month period: a retrospective study. The Angle Orthodontist, 96(3), 318-325. https://doi.org/10.2319/040925-281.1
Vancouver
Akcan CA, Aksoz G, Gorucu-Coskuner H, Akarsu-Guven B, Atik E. Evaluation of wear amounts of different composite resin attachments used in clear aligner treatment over a 6-month period: a retrospective study. The Angle Orthodontist. 2026;96(3):318-325. doi:10.2319/040925-281.1
BibTeX
@article{Akcan2026,
author = {Akcan, Cenk Ahmet and Aksoz, Gediz and Gorucu-Coskuner, Hande and Akarsu-Guven, Bengisu and Atik, Ezgi},
title = {Evaluation of wear amounts of different composite resin attachments used in clear aligner treatment over a 6-month period: a retrospective study},
journal = {The Angle Orthodontist},
year = {2026},
volume = {96},
number = {3},
pages = {318--325},
doi = {10.2319/040925-281.1}
}
EUVIMED