EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Investigation of hazardous waste a case study of electric arc furnace dust characterization

Vanja Trifunovic, Snezana Milic, Ljiljana Avramovic, Radojka Jonovic, Vojka Gardic, Stefan Djordjievski, Silvana Dimitrijevic

Hemijska industrija · 2022 · 76 (4) · 237-249

DOI: 10.2298/hemind220609018t ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hemijska industrija, 2022. Verfasst von Vanja Trifunovic und 6 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Science and Technological Development of the Republic of Serbia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dust from an electric arc furnace is formed as the main by-product of the steel production process from the secondary iron-based raw materials. This dust has significant contents of Zn and Fe, as well as Pb, Cd, Ca, Mg, Cr, Mn, Si, Ni, Cu, F, Cl and other elements and is considered hazardous industrial solid waste since it contains heavy metals. In order to protect the environment and public health from the negative impact of this type of hazardous waste, it is necessary, even mandatory, to carry out its treatment in accordance with the legislation of the country where it is located. Before applying any treatment of the electric arc furnace (EAF) dust, it is necessary to perform its detailed characterization. In this paper, the following characterization of EAF dust originating in the Republic of Serbia was performed: physical-mechanical and chemical characterization, determination of granulometric composition, and mineralogical characterization. Also, the EAF dust impact on the environment and human health was assessed (Leachability and Toxicity Characteristic Leaching Procedure (TCLP) tests). The results have shown that the Zn content is in the range 32 to 35 % and that the main mineralogical phases of the dust are zincite, franklinite, magnetite, and magnesioferrite. Granulometric analysis has shown that 80 % of the sample consists of particles less than 26 ?m in size. According to the leaching test results, the EAF dust is characterized as a hazardous waste due to the increased chloride content, while the TCLP test indicated dust toxicity due to the increased contents of Zn, Cd, and Pb.

Förderung

  • Ministry of Education, Science and Technological Development of the Republic of Serbia

Zitieren

APA

Trifunovic, V., Milic, S., Avramovic, L., Jonovic, R., Gardic, V., Djordjievski, S., & Dimitrijevic, S. (2022). Investigation of hazardous waste a case study of electric arc furnace dust characterization. Hemijska industrija, 76(4), 237-249. https://doi.org/10.2298/hemind220609018t

Vancouver

Trifunovic V, Milic S, Avramovic L, Jonovic R, Gardic V, Djordjievski S, et al. Investigation of hazardous waste a case study of electric arc furnace dust characterization. Hemijska industrija. 2022;76(4):237-249. doi:10.2298/hemind220609018t

BibTeX
@article{Trifunovic2022,
  author = {Trifunovic, Vanja and Milic, Snezana and Avramovic, Ljiljana and Jonovic, Radojka and Gardic, Vojka and Djordjievski, Stefan and Dimitrijevic, Silvana},
  title = {Investigation of hazardous waste a case study of electric arc furnace dust characterization},
  journal = {Hemijska industrija},
  year = {2022},
  volume = {76},
  number = {4},
  pages = {237--249},
  doi = {10.2298/hemind220609018t}
}
Kostenlos starten →