EUVIMEDOdkrijte EUVIMED
Crossref

A Non-Invasive Gas Exchange Monitor To Assess Swimming-Induced Pulmonary Edema

Yousef Ahmed, MD, Peter Lindholm MD, PhD, Nick Bartlett, BS, Michael Tripp, MD, Gil Boswell, MD, Charles Volk, MD

Undersea and Hyperbaric Medicine · 2026-06-28 · 53 (2) · 343-348

DOI: 10.22462/760 ↗

At a glance

Journal article in Undersea and Hyperbaric Medicine, published online on 2026-06-28. Written by Yousef Ahmed and 11 co-authors.

PovzetekBibliografski podatkiCiteRelated studies

Abstract (original language)

Ahmed Y, Lindholm P, Bartlett N, Tripp M, Boswell G, Volk C. A Non-Invasive Gas Exchange Monitor To Assess Swimming-Induced Pulmonary Edema. Undersea Hyperb Med. 2026 Second Quarter; 53(2):343-348.

Introduction

Swimming-induced pulmonary edema (SIPE) occurs in physically demanding environments. SIPE has been identified among U.S. Naval Special Warfare (NSW) candidates, risking trainees' lives or, less severely, preventing them from completing training. Diagnosis is based on clinical examination and chest X-ray. The MediPines gas exchange monitor AGM-100 is a noninvasive diagnostic tool approved by the FDA and used in hospital settings. This study aimed to assess noninvasive physiological parameters and evaluate the use of the AGM-100 in NSW candidates with SIPE.

Methods

In this observational study, eighteen subjects were tested (nine with confirmed SIPE). Data on a noninvasive surrogate for oxygen deficit, based on end-tidal oxygen (EtO2),carbon dioxide (EtCO2), and SpO2 were collected. Chest X-rays (CXR) were graded for interstitial and airspace edema.

Results

Subjects with confirmed SIPE displayed an oxygen deficit (28.1 ± 12.9 mm Hg), while eight of nine subjects without SIPE did not (3.1 ± 8.79 mm Hg, p < 0.001). There were no differences in EtCO2. SpO2 was lower in individuals with confirmed SIPE (95.1 ± 2.23%) compared to controls/unconfirmed SIPE (98.1 ± 0.31%, p-value < 0.0001). The group with the oxygen deficit had a correspondingly worse edema grade on CXR.

Discussion

These limited results showed a possible correlation between O2 deficit and SIPE, while the AGM-100 performed reliably in this prehospital setting. Future higher-powered studies are needed to substantiate these findings and the AGM-100's utility, possibly extending to other environments, such as combat field hospitals, for rapid diagnosis and severity assessment of pulmonary edema. Keywords: gas exchange; physiology; swimming-induced pulmonary edema

Cite

APA

Ahmed, Y., MD, MD, P. L., PhD, Bartlett, N., BS, Tripp, M., MD, Boswell, G., MD, Volk, C., & MD (2026). A Non-Invasive Gas Exchange Monitor To Assess Swimming-Induced Pulmonary Edema. Undersea and Hyperbaric Medicine, 53(2), 343-348. https://doi.org/10.22462/760

Vancouver

Ahmed Y, MD, MD PL, PhD, Bartlett N, BS, et al. A Non-Invasive Gas Exchange Monitor To Assess Swimming-Induced Pulmonary Edema. Undersea and Hyperbaric Medicine. 2026;53(2):343-348. doi:10.22462/760

BibTeX
@article{Ahmed2026,
  author = {Ahmed, Yousef and MD and MD, Peter Lindholm and PhD and Bartlett, Nick and BS and Tripp, Michael and MD and Boswell, Gil and MD and Volk, Charles and MD},
  title = {A Non-Invasive Gas Exchange Monitor To Assess Swimming-Induced Pulmonary Edema},
  journal = {Undersea and Hyperbaric Medicine},
  year = {2026},
  volume = {53},
  number = {2},
  pages = {343--348},
  doi = {10.22462/760}
}
Start for free →