EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

EVALUATION OF LOW-COST PM2.5 SENSOR ACCURACY IN COMPARISON WITH GOVERNMENT REFERENCE INSTRUMENT

Putri ayu Risti, Rizki Andre Handika, Fernando Mersa Putra

Lingkar: Journal of Environmental Engineering · 03.08.2026 · 7 (1)

DOI: 10.22373/ljee.v7i1.10530 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lingkar: Journal of Environmental Engineering, online erschienen am 03.08.2026. Verfasst von Putri ayu Risti und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air pollution in Jambi City, due to the increasing PM2.5, often exceeds the national quality standards. This situation requires a uniform monitoring solution, since the number of government reference stations is limited. An IoT-based monitoring system using low-cost sensors can be an alternative, which are flexible and real-time monitoring. We developed an IoT-based monitoring system using two low-cost sensors (PMS5003 and PMS7003), which were collocated with and validated against the BAM-1020 reference instrument operated by the Meteorology, Climatology, and Geophysics Agency (BMKG) at the Sultan Thaha Jambi Climatology Station. This quantitative study aims to evaluate the accuracy of the two sensors against the reference instrument for the period December 2025 to January 2026. The analysis was carried out using the statistical parameters MBE, MAE, RMSE, the correlation coefficient (r), and the coefficient of determination (R²), followed by a linear regression-based correction of the sensor readings. The results showed that both sensors were able to follow the pattern of changes in PM2.5 concentration quite well (R2 = 0.60 for PMS5003 and 0.59 for PMS7003), although they tended to produce higher values (overestimate). The PMS7003 sensor showed slightly better accuracy with a lower error rate (MBE=10.46; MAE=12.53; RMSE=18.02 µg/m3) compared to the PMS5003 (MBE=11.84; MAE=13.60; RMSE=19.60 µg/m3). This overestimation is consistent with the influence of high relative humidity and the technical limitation of light-scattering sensors, which cannot distinguish solid particles from water droplets, as reported in previous studies. Overall, both sensors are reliable for real-time monitoring, but still require further calibration.

Zitieren

APA

Risti, P. A., Handika, R. A., & Putra, F. M. (2026). EVALUATION OF LOW-COST PM2.5 SENSOR ACCURACY IN COMPARISON WITH GOVERNMENT REFERENCE INSTRUMENT. Lingkar: Journal of Environmental Engineering, 7(1). https://doi.org/10.22373/ljee.v7i1.10530

Vancouver

Risti PA, Handika RA, Putra FM. EVALUATION OF LOW-COST PM2.5 SENSOR ACCURACY IN COMPARISON WITH GOVERNMENT REFERENCE INSTRUMENT. Lingkar: Journal of Environmental Engineering. 2026;7(1). doi:10.22373/ljee.v7i1.10530

BibTeX
@article{Risti2026,
  author = {Risti, Putri ayu and Handika, Rizki Andre and Putra, Fernando Mersa},
  title = {EVALUATION OF LOW-COST PM2.5 SENSOR ACCURACY IN COMPARISON WITH GOVERNMENT REFERENCE INSTRUMENT},
  journal = {Lingkar: Journal of Environmental Engineering},
  year = {2026},
  volume = {7},
  number = {1},
  doi = {10.22373/ljee.v7i1.10530}
}
Kostenlos starten →