SIA Vector Analysis and Keratometry Prediction in Temporal SICS with 350 μm Scleral Incision Depth
romanian journal of ophthalmology · 30.07.2026 · 70 (2)
DOI: 10.22336/rjo.2026.34 ↗Kurz gefasst
Fachartikel in der Zeitschrift romanian journal of ophthalmology, online erschienen am 23.07.2026. Verfasst von Prabhakar Srinivasapuram Krishnacharya und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, JSS Hospital, Mysore, Karnataka, India. Hauptthemen laut MEDLINE: Sclera, Astigmatism, Cornea, Corneal Topography. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
The magnitude and axis of surgically induced astigmatism depend on the sclera-corneal tunnel dimensions. Often, the incision depth is subjective, and standardization is rarely emphasized. This study attempts to evaluate a fixed scleral incision depth of 350 µm at 1-week post-op. The aim is to determine the SIA vector and centroid using the Pythagorean theorem and keratometric measurements. Materials and methods: This study was conducted from January to July 2025 and recruited 42 patients at a tertiary health institution. All patients received scleral incisions to a depth of 350 µm after preoperative auto-keratometry measurements. Preoperative astigmatism was classified into WTR, ATR, and oblique types. Results: values of 0.93 and 0.74, respectively).
Discussion
This work adds a unique dimension to the literature by explicitly linking a fixed tunnel depth to the SIA vector and keratometric prediction. These results provide a platform for future research exploring scleral incision depth as a determinant of astigmatic outcomes.
Conclusions
This study finds a statistically significant difference in vertical keratometry with moderate SIA magnitude. Astigmatic axis transition was unchanged in most patients, likely due to a standardized scleral incision depth. Centroid demonstrated a minimal SIA magnitude on horizontal keratometry. An excellent postoperative keratometry prediction was determined.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, JSS Hospital, Mysore, Karnataka, India.
Zitieren
APA
Krishnacharya, P. S., Prabhu, K. J., Nataraj, S., Cyprian, A., & Belagutti, P. P. (2026). SIA Vector Analysis and Keratometry Prediction in Temporal SICS with 350 μm Scleral Incision Depth. romanian journal of ophthalmology, 70(2). https://doi.org/10.22336/rjo.2026.34
Vancouver
Krishnacharya PS, Prabhu KJ, Nataraj S, Cyprian A, Belagutti PP. SIA Vector Analysis and Keratometry Prediction in Temporal SICS with 350 μm Scleral Incision Depth. romanian journal of ophthalmology. 2026;70(2). doi:10.22336/rjo.2026.34
BibTeX
@article{Krishnacharya2026,
author = {Krishnacharya, Prabhakar Srinivasapuram and Prabhu, Kedar Janardhan and Nataraj, Shreya and Cyprian, Anisha and Belagutti, Preethi Prasanna},
title = {SIA Vector Analysis and Keratometry Prediction in Temporal SICS with 350 μm Scleral Incision Depth},
journal = {romanian journal of ophthalmology},
year = {2026},
volume = {70},
number = {2},
doi = {10.22336/rjo.2026.34}
}
EUVIMED